MEC20-00915
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 3:41:21 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe- furnace a/c coil co locking caps ok
|
MEC20-00911
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 3:04:13 PM | P | PASS |
|
|
Alex ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- final co ok
|
MEC20-00911
| Pressure Test | 3/3/2020 | 3/4/2020 | 3/4/2020 3:03:54 PM | P | PASS |
|
|
Alex ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 20lb gas pas from meter to range and bbq- 2 gas valves with open tee installed at meter
|
MEC19-05378
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 2:26:30 PM | P | FAIL |
|
|
AC: 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves 1- single wall water heater flue needs 6" clearance to sheetrock 2- condenser pad needs to be level 3- need to support water heater flue
|
MEC19-05381
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 2:25:08 PM | P | FAIL |
|
|
AC: 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves 1- single wall water heater flue needs 6" clearance to sheetrock 2- condenser pad needs to be level
|
MEC20-00581
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 1:37:00 PM | P | PASS |
|
|
Please call landlord Allan Montgomery prior to inspection so he can open house for you. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC20-00928
| Rough-in | 3/4/2020 | 3/4/2020 | 3/4/2020 12:51:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
|
MEC20-00928
| Pressure Test | 3/4/2020 | 3/4/2020 | 3/4/2020 12:50:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location
|
MEC20-00215
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 12:39:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
|
MEC20-00216
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 12:38:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
|
MEC20-00217
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 12:28:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
|
MEC20-00929
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 12:21:03 PM | P | CANC |
|
|
>> Inspection requested via web by Margie Rowe Inspection cancelled from web by: Margie Rowe
|
MEC19-02519
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 11:26:47 AM | A | PASS |
|
|
final ok- mini split inspected
|
MEC19-05521
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 11:02:16 AM | A | PASS |
|
|
AC: 2020 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
|
MEC20-00900
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 10:39:42 AM | A | PASS |
|
|
Please give us 30 minutes notice to provide a ladder for roof access. Phone #: ###-#### Inspection requested via web by Ted Dumont Inc.- 5 ton RTU ok
|
MEC19-04242
| Rough-in | 3/3/2020 | 3/4/2020 | 3/4/2020 9:59:15 AM | A | PASS |
|
|
Rough-in for cover, 2nd layer grease duct, dishwasher hood, Admin Area B1 Phone #: ###-#### Inspection requested via web by RM Mechanical- 2nd layer firewrap ok from hoods thru curb- MAU insulation all drops in kitchen and duct work ok- kitchen diffusers, flex and insulation ok- missing insulation in storage room supply duct above hard lid- dishwasher exhaust duct and seal ok
|
MEC19-05464
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 9:25:14 AM | A | PASS |
|
|
Please call Shea for access Phone #: ###-#### Inspection requested via web by max sanders- final ok
|
MEC20-00926
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 9:06:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP 1- need to submit acca report to city of boise for approval/ include erv in crawl with this on how is currently installed 2- need to insulate bare metal supply and return in crawl/ no exposed metal can be showing on taps too 3- need to support ducting in crawl in couple places 4- need to support line set at condenser and uv protect 5- mc cable needs approved ul listed weather tight fitting on condenser mc cable can not just pass thru appliance
left notice kitchen counter- GC onsite too
|
MEC20-00899
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 8:37:50 AM | A | PASS |
|
|
8AM INSPECTION REQUESTED GUNNER ###-#### - CALL 30 MIN IN ADVANCE Phone #: ###-#### Inspection requested via web by Mike Almanza- log set final ok
|
MEC20-00899
| Rough-in | 3/3/2020 | 3/4/2020 | 3/4/2020 8:37:30 AM | A | PASS |
|
|
8AM INSPECTION REQUESTED GUNNER ###-#### - CALL 30 MIN IN ADVANCE Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC19-02126
| Mec-Aging Inspection | 3/4/2020 | 3/4/2020 | 3/4/2020 7:49:08 AM | | DONE |
|
|
permit expired
|
MEC19-02126
| DOC - Permit Expired | 3/4/2020 | 3/4/2020 | 3/4/2020 7:48:50 AM | A | PASS |
|
|
no calls no activity- permit expired
|