ELE19-04567
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 2:30:30 PM | P | PASS |
|
|
Replace 3 sets of wall signs with new signs reading Good Burger. All Primary power to remain as is. Phone #: ###-#### Inspection requested via web by Ken Olsen Ok final. Disconnects on left side of all signs
|
ELE19-00947
| Electrical Rough-In | 3/4/2020 | 3/4/2020 | 3/4/2020 2:02:49 PM | P | PASS |
|
|
andy Phone #: ###-#### Ok cover 1st floor corridor celings
|
ELE20-00743
| Conference | 3/3/2020 | 3/4/2020 | 3/4/2020 1:33:30 PM | P | DONE |
|
|
call for access- John Phone #: ###-#### Discussed the adding of 4 external heaters, 2 front porch, 2 on pergola on S side. Service is 100a with a split buss that is full. Then discussed possible service change to 200a to accomodate new heater additions. Each heater requires a 30a 240 circuit.
|
ELE19-04633
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 12:33:48 PM | P | PASS |
|
|
Garage code 1977 Phone #: ###-#### Inspection requested via web by ERIC CENTERS Ok final.
|
ELE20-00100
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 12:33:14 PM | A | PASS |
|
|
7190 Phone #: ###-#### Inspection requested via web by Alan Lusk Ok final kitchen, lockout on hood.
|
ELE20-00721
| Final | 3/4/2020 | 3/4/2020 | 3/4/2020 11:33:47 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve sellers Panel labeled, intersystem installed.
|
ELE20-00752
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 10:55:45 AM | A | FAIL |
|
|
Shea Phone #: ###-#### 1. All receptacles need to be tamper resistant. 2. All devices need installed. Dryer outlet, door bell chime kit due to 110v connection. 3. Sparks rings needed in kitchen. 4. Remove wires in conduit to left of panel outside. They are already disconnected. 5. Misc plates need installed.
|
ELE19-03145
| Electrical Rough-In | 3/4/2020 | 3/4/2020 | 3/4/2020 10:25:46 AM | A | PASS |
|
|
1st, 3rd, ; 4th floor community areas. Phone #: ###-#### Inspection requested via web by Kevin Burke Ok cover areas listed.
|
ELE19-04945
| Electrical Rough-In | 3/3/2020 | 3/4/2020 | 3/4/2020 10:25:25 AM | A | PASS |
|
|
For access please call Matt 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Ok cover whole house
|
ELE19-04923
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 10:02:43 AM | A | PASS |
|
|
Give me a call when your headed over there all make sure somebody there to let you in. Phone #: ###-#### Inspection requested via web by David Kubik Ok final.
|
ELE20-00758
| Electrical Rough-In | 3/3/2020 | 3/4/2020 | 3/4/2020 9:51:38 AM | A | PASS |
|
|
Call 30 minutes before arriving ###-#### Phone #: ###-#### Inspection requested via web by Eric Schroeder Ok cover small house.
|
ELE20-00759
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 9:38:47 AM | A | PASS |
|
|
Please call Nate ###-#### with a heads up on your way. If you have any questions please feel free to Contact Jason ###-####. Thanks! Phone #: ###-#### Inspection requested via web by Clayton Morgan Ok final TR recept in 4 sq for fireplace insert
|
ELE19-04398
| Final | 3/3/2020 | 3/4/2020 | 3/4/2020 5:02:33 AM | A | PASS |
|
|
This permit was for Rough-In only. Home owner has pulled their own permit to finish the projeoct (ELE20-00752) If you can please close this permit. Phone #: ###-#### Inspection requested via web by Noah Giver Talked to Noah on 3/3 about home RI. Homeowner pulled permit to finish project. This is to close out permit for electrician. Homeowner permit 20-00752.
|