Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03758 Final3/5/20083/5/20083/5/2008 3:47:58 PMPPASS
looked at sign, ok to final
ELE07-01163 Final3/5/20083/5/20083/5/2008 3:23:52 PMPPASS
Scheduled by a contractor via Hello! on 3/5/2008 at 8:49:47 AM. Contact: ###-####. corrections made, ok to final, signed occupancy safd
ELE07-01160 Final3/5/20083/5/20083/5/2008 2:47:25 PMPPASS
Scheduled by a contractor via Hello! on 3/5/2008 at 8:47:37 AM. Contact: ###-####. corrections made, ok to final, signed occupancy card
ELE08-00517 Electrical Rough-In3/5/20083/5/20083/5/2008 1:50:56 PMPPASS
Please inspect service. electrician is Jon Fivecoat @ ###-#### Phone #: ###-#### Internet Inspection Request from: gary batten ric ok
ELE08-00517 Permanent Service3/5/20083/5/20083/5/2008 1:27:42 PMPPASS
Please inspect service. electrician is Jon Fivecoat @ ###-#### Phone #: ###-#### Internet Inspection Request from: gary batten p/s o/h rec ok
ELE08-00517 Final3/5/20083/5/20083/5/2008 1:27:00 PMPPASS
Please inspect service. electrician is Jon Fivecoat @ ###-#### Phone #: ###-#### Internet Inspection Request from: gary batten ok to final
ELE08-00406 Electrical Rough-In3/5/20083/5/20083/5/2008 1:13:39 PMPNR
joe Note: ufier Phone #: ###-#### called contractor, said to call for am inspection
ELE08-00544 Electrical Rough-In3/5/20083/5/20083/5/2008 12:22:13 PMPPASS
location is at the bmc west truss plant that is behind franklin building supply by railroad tracks. contact person on site is schawn. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok
ELE08-00544 Final3/5/20083/5/20083/5/2008 12:21:55 PMPPASS
location is at the bmc west truss plant that is behind franklin building supply by railroad tracks. contact person on site is schawn. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final
ELE07-03444 Final3/4/20083/5/20083/5/2008 11:51:02 AMAPASS
rod Phone #: ###-#### ok to final
ELE07-03444 Electrical Rough-In3/5/20083/5/20083/5/2008 10:46:12 AMAPASS
rod Phone #: ###-#### ric ok
ELE08-00024 Final3/5/20083/5/20083/5/2008 10:43:38 AMAPASS
ready Phone #: ###-#### Internet Inspection Request from: dennis mcneely ok to final
ELE08-00534 Permanent Service3/4/20083/5/20083/5/2008 10:29:22 AMAFAIL
john Phone #: ###-#### called, left correction notice, BCC shall provide access to building for inspection, NEC 230.70 shall provide disconnect to disconnect all conductors from service entrance conductors
ELE07-03378 Final3/4/20083/5/20083/5/2008 10:03:31 AMAFAIL
Scheduled by a contractor via Hello! on 3/4/2008 at 12:44:45 PM. Contact: ###-####. called contractor, left correction notice, NEC 406.4(D) receptacles faces shall be flush with or project from faceplates,404.4 switches shall not be installed in tub area, 348.30(A) fmc shall be fastened within 12" of box, 300.10 shall securely fasten raceway fitting to box, 400.8 shall not use flexible cord in lieu of permanent wiring, BCC shall provide globe guard for undercounter fixture, shall provide listing for control box for pump controller
ELE07-01170 Final3/5/20083/5/20083/5/2008 9:31:07 AMAPASS
Scheduled by a contractor via Hello! on 3/5/2008 at 6:45:36 AM. Contact: ###-####. ok to final, signed occupancy card
ELE07-02511 Final3/5/20083/5/20083/5/2008 8:56:43 AMAPASS
Scheduled by a contractor via Hello! on 3/5/2008 at 6:44:05 AM. Contact: ###-####. met contractor, ok to final, signed occupancy card
ELE08-00100 Electrical Rough-In3/4/20083/5/20083/5/2008 8:10:09 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Todd Sellman corrections made, ok to cover 1st floor hall and kitchenette walls only