Inspections for the day of: Thursday, March 5, 2020.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02412 ELE-Aging Inspection3/5/20203/5/20203/11/2020 6:05:23 AM DONE
Please call the city and request an extension if more time is needed.
ELE20-00419 Electrical Rough-In3/3/20203/5/20203/5/2020 2:40:00 PMPPASS
Electrical rough-in for a solar system. Phone #: ###-#### Inspection requested via web by Bryan Lawley Items UL listed, panels match paperwork
ELE20-00602 Rough-In Permanent Service3/4/20203/5/20203/5/2020 1:48:01 PMPPASS
Customer Sean wants a call before you get there if possible. Thank you!!! ###-#### Phone #: ###-#### Inspection requested via web by Tricia Henderson Contractor going back for other work. He will finish driving last grd rod a few more inches in. p/s o/h rec ok
ELE20-00229 Final3/5/20203/5/20203/5/2020 1:07:46 PMPPASS
Got the electrical redone around the panel and grounded with two ground rods and refed 4 wires to each panel with grounds separated from neutrals. Also got service outlets added. Call with any questions thanks! Phone #: ###-#### Inspection requested via web by Trevor Soesbe Ok final. Corrections made.
ELE19-03017 Electrical Rough-In3/5/20203/5/20203/5/2020 12:50:17 PMPPASS
ceiling inspection south wing.
consult on disconnect locations roof Phone #: ###-#### Inspection requested via web by Debby Pierce Ok cover ceilings S side classrooms. Disconnects for units on rooftop clearance ok.
ELE19-02224 Electrical Rough-In3/4/20203/5/20203/5/2020 12:36:35 PMPPASS
Wall rough-in inspection 3rd floor area ''A'' west block of exam rooms, all of north rooms, and south lobby. Also need conference concerning clearance of split unit 1st floor emergency electrical room 1E292. Call Lonny when on site. Thanks. Phone #: ###-#### Inspection requested via web by Lonny Baum Ok cover areas listed. 3rd floor elec room has 3 mini splits. Center mini split cannot be above elec UPS 110.26(E)(1)(A) Equipt needs minimum 6' clearence above from any foreign systems
ELE20-00257 Electrical Rough-In2/27/20203/5/20203/5/2020 12:01:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Kilee Russell Items UL listed
ELE20-00782 Temporary Service3/5/20203/5/20203/5/2020 11:44:28 AMPPASS
Phone #: ###-#### Inspection requested via web by Robert Murray t/s o/h n ok
ELE20-00688 Electrical Rough-In3/5/20203/5/20203/5/2020 11:12:55 AMPPASS
Guys will be onsite Phone #: ###-#### Inspection requested via web by Jesse Simpson Items UL listed
ELE20-00770 Electrical Rough-In3/4/20203/5/20203/5/2020 10:34:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga Ok cover walls 3 offices and hallway space.
ELE18-00250 Electrical Rough-In3/4/20203/5/20203/5/2020 10:33:37 AMAPASS
Gregory Phone #: ###-#### Ok cover garage and space above.
ELE19-04825 Final3/4/20203/5/20203/5/2020 10:33:10 AMAPASS
This was on a service change we did a meter panel. Any questions please give me a call thank you Phone #: ###-#### Inspection requested via web by David Kubik Ok final. Intersystem installed, panel labeled. No work done inside.
ELE20-00098 Electrical Rough-In3/4/20203/5/20203/5/2020 9:51:33 AMAPASS
rough in for the floor heat in the master bedroom only Phone #: ###-#### Inspection requested via web by Nermin Bobaric Ok cover floor heat mstr.