Inspections for the day of: Thursday, March 5, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-00781 Final3/5/20203/5/20203/5/2020 2:47:34 PMPPASS
Phone #: ###-#### Inspection requested via web by Tricia Henderson...ok to final...surface mounted with m/c and metal box...GFCI outlet
ELE19-04581 Electrical Rough-In3/5/20203/5/20203/5/2020 2:22:57 PMPPASS
Phone #: ###-#### Inspection requested via web by Brad Girard...walls and bath hardlids ok to cover
ELE20-00724 Electrical Rough-In3/5/20203/5/20203/5/2020 1:31:20 PMPPASS
Contact: Jeremy Thornock. underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden...
under slab pipes...ok to cover
ELE19-04821 Electrical Rough-In3/4/20203/5/20203/5/2020 11:49:48 AMAPASS
16700 Only
Above grid tray and cable management final Phone #: ###-#### Inspection requested via web by David Seilheimer...discussed track and jbolts for hanging...went over bonding requirements...5 connections verified...ok to cover with grid
ELE20-00645 Electrical Rough-In3/4/20203/5/20203/5/2020 10:55:01 AMAPASS
Site Contact is Ryan Weidrich Phone #: ###-#### Inspection requested via web by Scott Campbell...ok to cover new walls of office-switch and one outlet
ELE19-04125 Final3/4/20203/5/20203/5/2020 10:04:20 AMAFAIL
Lock Box on back door is 2019 any questions please let me know thank you Phone #: ###-#### Inspection requested via web by David Kubik....
1) outside service panel needs labelling
2) light required at ea egress...house and detached building-backdoor of house needs verified working...no lamps
3)water heater shall have a disconnect within sight
4) disconnect shall be clearly labelled with its on/off position..furnace disconnect
5) outlets shall be free of faults/shorts...kitchen receptacles and switches need completed...plates and installed to boxes...kitchen tile area
6) a weather proof outlet/recepticle is required at the front and back of single family dwellings-front of house
7) auxillarry building/garage needs a grounding electrode installed
ELE20-00767 Electrical Rough-In3/4/20203/5/20203/5/2020 9:09:57 AMAPASS
call ahead // groundwork // Larry Phone #: ###-####...ok to cover...groundwork under driveway/parking lot entrance and back
ELE19-04713 Final3/4/20203/5/20203/5/2020 8:38:56 AMAPASS
Garage Code 2020 Phone #: ###-#### Inspection requested via web by Dean Gernaat...
ok to final