ELE07-00730
| Permanent Service | 3/6/2007 | 3/6/2007 | 3/7/2007 6:29:14 AM | P | NR |
|
|
brenda Note: storage shed will be relocated from pole for clearance; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contr, no grounding done,shed in way, still making up service, no mis permit for trailer, ipco called late pm, 370 said ok to install meter as tenant would not have power overnight, but called to have contr recall for inspection, and said that possible to pull meter if violations remain. Contr called later and said that park had crew to move shed on Wednesday, and they will find out about MIS for tie-downs.
|
ELE06-00680
| ELE-Aging Inspection | 3/6/2007 | 3/6/2007 | 3/6/2007 3:50:24 PM | | DONE |
|
|
ok to final, see final
|
ELE06-00680
| Final | 3/6/2007 | 3/6/2007 | 3/6/2007 3:49:18 PM | P | PASS |
|
|
ok to final
|
ELE07-00623
| Conference | 3/6/2007 | 3/6/2007 | 3/6/2007 3:48:23 PM | P | DONE |
|
|
Would like to conference about the grounding issues for this loction and project. Phone #: ###-#### talked about gec and grounding 2nd point of service
|
ELE06-01478
| Electrical Rough-In | 3/6/2007 | 3/6/2007 | 3/6/2007 2:54:53 PM | P | PASS |
|
|
pole base ins. on parking lot lights Phone #: ###-#### u/g already done, called and said pole base grounding shall be per spec or design, we look at as branch circuits at final
|
ELE07-00731
| Permanent Service | 3/6/2007 | 3/6/2007 | 3/6/2007 2:23:45 PM | P | NR |
|
|
brenda .; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contr, supposed to be later
|
ELE07-00732
| Permanent Service | 3/6/2007 | 3/6/2007 | 3/6/2007 2:23:02 PM | P | NR |
|
|
brenda - ###-#### met contr, supposed to be tomorrow
|
ELE07-00726
| Temporary Service | 3/6/2007 | 3/6/2007 | 3/6/2007 1:36:32 PM | P | FAIL |
|
|
brandon ###-#### called contr, left corr notice, nec 110.26(A)(1)work space shall be provided about elect equipment-depth
|
ELE07-00682
| Electrical Rough-In | 3/5/2007 | 3/6/2007 | 3/6/2007 1:12:03 PM | P | PASS |
|
|
Requesting an inspection to cover. Phone #: ###-#### walls and hard lids ok to cover only, told elect pull box not allowed under foreign piping
|
ELE07-00516
| Final | 3/6/2007 | 3/6/2007 | 3/6/2007 12:34:45 PM | P | PASS |
|
|
9411713 ok to final, no card to sign
|
ELE07-00098
| Final | 3/6/2007 | 3/6/2007 | 3/6/2007 12:20:04 PM | P | PASS |
|
|
Lynn; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
For both units ok to final, signed occ card
|
ELE07-00693
| Electrical Rough-In | 3/6/2007 | 3/6/2007 | 3/6/2007 10:22:55 AM | P | PART |
|
|
joe ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to cover lower rear soffit only
|
ELE07-00712
| Temporary Service | 3/5/2007 | 3/6/2007 | 3/6/2007 10:14:19 AM | A | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Victoria Beall t/s u/g n ok
|
ELE07-00704
| Electrical Rough-In | 3/5/2007 | 3/6/2007 | 3/6/2007 10:00:42 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 3/5/2007 at 4:55:32 PM. Contact: ###-####. called, left message, nec 250.92 (A)(3) metallic raceway enclosing gec shall be bonded at each end, 250.53(C)(2) water system shall be supplemented by electrodes and bonded to grounded service conductor, 250.70 listed and approved connections shall be used for gec, 352.30(A) rnc shall be securely fastened within 3' of termination, 314.17(C) nm cable shall be secured within 8"of box, 210.52(A)(2) wall spaces over 2' shall have recpt installed, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member, 210.52(E) shall provide outlet at front of dwelling, 110.26(F)(1)(a) there shall be no foreign piping systems over equipment, 110.12(A) there shall be no broken parts (boxes), 300.14 at least 6" of free conductor shall be in each box, Bcc all make-up shall be done, grounds together, Reserved right to amend corr notice, left do not cover sticker
|
ELE07-00009
| Final | 3/5/2007 | 3/6/2007 | 3/6/2007 8:33:45 AM | A | PASS |
|
|
alan ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to final
|
ELE07-00182
| Final | 3/5/2007 | 3/6/2007 | 3/6/2007 7:53:05 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/5/2007 at 9:20:25 PM. Contact: ###-####. ok to final, signed occ card
|