Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR07-01000 INSP-Final Inspection3/5/20083/6/20083/7/2008 10:48:55 AMPFAIL
Site inspection comments per K.Roule
Tested FA monitoring of VT and waterflow (by manual means). Both annunciated correctly at panel and offsite monitoring station. Visually observed location of dry sidewall sprinkler installed in exterior chimney. Work remaining on this permit:
1. Test the new fire alarm monitoring module which was installed on the existing cooking hood suppression system under this permit. (Requires the hood fire suppression system contractor to be present)
2. Test the waterflow alarm switch by flowing water from the test connection. (Requires the sprinkler contractor responsible for FIR04-00490 be present).
3. Provide fire alarm-initiated interlocks which shut off the hood exhaust fan and the gas fuel to the cooking appliances, as specified in the signed Fire Department Agreement dated 2/4/2004 and in F.Varley's letter dated 4 Feb 2002 letter (Item 2).
4. Correct the existing "trouble" condition on the fire alarm panel.
5. Provide an updated alarm map reflecting the current floor plan and all initiating device locations correlated with the annunciated fire alarm device addresses. (NFPA 72 4.4.6.1).
6. Replace the missing door latch on the FACP cabinet and update the outdated monitoring company and account information currently posted inside the cabinet.
FIR06-00540 INSP-Sprinkler Rough-in/Hydro3/5/20083/6/20083/6/2008 5:08:24 PMPPART
Inspection for the seismic upgrade areas at the plaza level to be completed in conjunction with the hydrostatic test for this level per agreement.
BLD06-03315 FIRE-Final Inspection3/6/20083/6/20083/6/2008 5:02:30 PMPPASS
Fire life safety is satisfactory.
BLD06-03316 FIRE-Final Inspection3/6/20083/6/20083/6/2008 5:01:58 PMPPASS
Fire life safety is satisfactory.
BLD06-03311 FIRE-Final Inspection3/6/20083/6/20083/6/2008 5:01:09 PMPPASS
Fire life safety completed acceptable.
BLD06-03310 FIRE-Final Inspection3/6/20083/6/20083/6/2008 5:00:28 PMPPASS
Fire life safety completed acceptable.
BLD06-03306 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:59:38 PMPPASS
Fire life safety completed acceptable.
BLD06-03519 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:58:50 PMPPASS
Fire life safety passed.
BLD06-03522 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:58:05 PMPPASS
Fire life safety passed.
BLD06-03523 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:57:20 PMPPASS
Fire life safety finaled.
BLD06-03524 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:56:48 PMPPASS
Fire life safety finaled.
BLD06-03526 FIRE-Final Inspection3/6/20083/6/20083/6/2008 4:55:45 PMPNR
Project job site is not in condition for final fire life safety approval.
FIR08-00080 INSP-Sprinkler Rough-in3/6/20083/6/20083/6/2008 4:52:28 PMPPART
OH sprinkler rough-in is approved for cover at the drop ceiling areas within the tenant remodel area.
BLD07-02081 FIRE-Final Inspection3/6/20083/6/20083/6/2008 2:41:39 PMPFAIL
Missing doors and hardware at both restrooms, need to provide and post one PFE for each level per fire code review notes, provide building address as discussed facing 10th street.
BLD06-03305 FIRE-Final Inspection3/6/20083/6/20083/6/2008 12:57:53 PMPNR
Project is not in condition for final at this time due to construction underway, finishes not complete, missing door hardware, etc.
BLD06-03521 FIRE-Final Inspection3/6/20083/6/20083/6/2008 12:55:58 PMPFAIL
Missing smoke seal at the back exit, need to adjust the closure at the trash chute door in the common corridor.
BLD06-03520 FIRE-Final Inspection3/6/20083/6/20083/6/2008 12:54:13 PMPFAIL
Missing escutcheon at the master bath, provide smoke seal at the back exit door.
FIR07-00324 INSP-Final Inspection3/6/20083/6/20083/6/2008 12:51:55 PMANR
In duct detectors and general alarm notification devices tested okay, final pending testing of single station smoke alarms when project is in condition for final.
FIR07-00648 INSP-Final Inspection3/6/20083/6/20083/6/2008 12:48:33 PMAPASS
Final fire alarm testing passed, permit finaled.
FIR07-00466 INSP-Final Inspection3/6/20083/6/20083/6/2008 12:47:35 PMAPASS
Final fire alarm testing completed satisfactory, permit finaled.
BLD07-03159 FIRE-Final Inspection3/5/20083/6/20083/6/2008 11:23:04 AMAPASS
Fire life safety inspection completed acceptable, suite address numbers to be posted at the common corridor as discussed.
BLD07-03158 FIRE-Final Inspection3/5/20083/6/20083/6/2008 11:21:21 AMAPASS
Fire life safety finaled.
BLD07-03157 FIRE-Final Inspection3/5/20083/6/20083/6/2008 11:20:36 AMAPASS
Fire life safety final inspection passed.