Inspections for the day of: Wednesday, March 6, 2013.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00169 ELE-Aging Inspection3/6/20133/6/20133/8/2013 2:28:39 PM DONE
Called, will call for final
ELE12-00171 ELE-Aging Inspection3/6/20133/6/20133/6/2013 2:54:18 PM DONE
Drove by and performed inspection
ELE12-00171 Final3/6/20133/6/20133/6/2013 2:53:42 PMPPASS
Drove by nad performed inspection. Final ok
ELE08-00958 Final3/6/20133/6/20133/6/2013 2:29:10 PMPPASS
Scope of work cover by ELE12-03055 for 1st floor and basement. 2nd floor to be permitted separately on future project.
ELE12-01710 Electrical Rough-In3/5/20133/6/20133/6/2013 2:22:06 PMPFAIL
Contact: Wes Powell, wall rough-in inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden
NEC 330.17 Where MC cable running through framing members shall be protected from physical damage in accordance with 300.4.
NEC 330.24 (B) Bends in MC cable shall be made so that the cable will not be damaged.
NEC 110.26 (F)(1) Indoor dedicated electrical space equal to the width and depth of the equiptment extending 6' above equiptment. Duct work located with in space.
Dry wall installed on 1st floor of electrical room before inspection was performed
ELE13-00502 Rough-In Permanent Service3/6/20133/6/20133/6/2013 1:12:56 PMPPASS
Phone #: ###-#### >> Inspection requested via web by mike brown Rough in ok cover p/s u/g n ok
ELE13-00500 Temporary Service3/5/20133/6/20133/6/2013 11:34:06 AMAPASS
THANK YOU Phone #: ###-#### >> Inspection requested via web by Bob Glenn
t/s u/g n ok
ELE13-00499 Temporary Service3/5/20133/6/20133/6/2013 11:14:05 AMAPASS
THANK YOU Phone #: ###-#### >> Inspection requested via web by Bob Glenn
t/s u/g n ok
ELE13-00044 Final3/5/20133/6/20133/6/2013 11:05:38 AMAPASS
code 10020 Phone #: ###-#### >> Inspection requested via web by Bob Glenn
Final ok
ELE13-00471 Rough-In Permanent Service3/5/20133/6/20133/6/2013 10:31:11 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Candi Bahem
Rough in ok cover p/s u/g n ok
ELE11-02806 Electrical Rough-In3/6/20133/6/20133/6/2013 9:58:42 AMAFAIL
Ceiling inspection on 3 and 4th floor north end. Please call Mike 30 min, prior at ###-####. Phone #: ###-#### >> Inspection requested via web by Shawna Gates 3rd floor- Multiple violations created by steel beam support. conduits unsupported, open knock-outs in boxes, data wiring supported by grid.
4th floor not ready.
ELE13-00488 Temporary Service3/5/20133/6/20133/6/2013 8:51:02 AMAPASS
Got the address corrected thanks Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok