Inspections for the day of: Wednesday, March 7, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-00456 Final3/6/20183/7/20183/7/2018 3:55:16 PMPPART
Phone #: ###-#### Inspection requested via web by Marisa Hone- need electrical permit pulled to final out
MEC18-00847 Rough-in3/7/20183/7/20183/7/2018 2:50:27 PMPPASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
MEC18-01060 Final3/7/20183/7/20183/7/2018 2:47:19 PMPCANC
Late PM. Plumbing final scheduled too. Please call on way. Craig ###-####. Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC18-00916 Pressure Test3/7/20183/7/20183/7/2018 2:25:39 PMPPASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
MEC18-00916 Rough-in3/7/20183/7/20183/7/2018 2:25:24 PMPPASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
MEC18-01062 Rough-in3/7/20183/7/20183/7/2018 1:53:26 PMPFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- furnace installed doesnt match manual J model #- need to support flex duct in crawl per manu install instructions no sags- insulation shield on fireplace flue needs to run full height to roof so no insulation can get on it- correction notice front window
MEC18-01062 Pressure Test3/7/20183/7/20183/7/2018 1:51:09 PMPPASS
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass- 5lb flue pass
MEC16-04905 Mec-Aging Inspection3/7/20183/7/20183/7/2018 11:21:12 AM FAIL
never called in for final inspection
MEC17-00437 Mec-Aging Inspection3/7/20183/7/20183/7/2018 11:20:45 AM FAIL
never called in for final inspection
MEC18-01062 Pressure Test3/6/20183/7/20183/7/2018 11:19:53 AMACANC
LATE PM Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC18-01062 Rough-in3/6/20183/7/20183/7/2018 11:19:11 AMACANC
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC18-00874 Rough-in3/6/20183/7/20183/7/2018 9:06:10 AMAPART
Justin Phone #: ###-####- registers flex in south lobby high ceiling ok for ceiling tiles
MEC18-00753 Rough-in3/6/20183/7/20183/7/2018 8:47:45 AMAFAIL
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gas test fail- b vent insulation shild at water heater locstion needs 1" clearance and secured- exhaust fans need sealed where 90 degree attaches to fan- need ladder to access furnace in attic- need nail plates on condensate drain at ceiling location- correction notice in front window
MEC18-00753 Pressure Test3/6/20183/7/20183/7/2018 8:44:00 AMAFAIL
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gauge at 3psi
MEC18-00287 Final3/6/20183/7/20183/7/2018 8:27:47 AMAPASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- final ok
MEC18-01020 Pressure Test3/5/20183/7/20183/6/2018 3:14:41 PMACANC
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
MEC18-01020 Rough-in3/5/20183/7/20183/6/2018 3:14:39 PMACANC
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
MEC18-01022 Pressure Test3/5/20183/7/20183/6/2018 3:14:34 PMACANC
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
MEC18-01022 Rough-in3/5/20183/7/20183/6/2018 3:14:32 PMACANC
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard