Inspections for the day of: Friday, March 8, 2019.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00826 Electrical Rough-In3/8/20193/8/20193/8/2019 3:14:40 PMPCANC
Brandon-but call homeowner when on way Rick ###-#### Phone #: ###-####
Owner asked to reschedule, he is busy at work
ELE19-00809 Final3/8/20193/8/20193/8/2019 2:46:03 PMPNH
gas furnace wiring ready for inspection. Tenant should be there this afternoon Phone #: ###-#### Inspection requested via web by Kelly Felin Door locked, note stated all agents at jail. Recall when accessible
ELE18-03892 Final3/7/20193/8/20193/8/2019 2:28:44 PMPFAIL
Etta Phone #: ###-####
110.3- Open ground and up receptacle not working. Mechanical room and pantry show open grounds.
250.140- Range and dryers shall be 4 wire receptacles.
210.70- Exterior lights shall operate at all exterior entrances. finish patio ceiling.
314.16- Disposal box shall have 16 cubic inch minimum for conductors installed.
314.29- Boxes shall be fully accessible under cooktop.
334.12- NM cable shall be protected from damage under sink and shall not be installed in damp locations. Patio.
348.30- Strap furnace flex with in 12" of a box and rest not to exceed 3'.
406.6- Receptacles and switches shall have proper covers. few missing.
406.9- Receptacles installed outdoors shall be weather resistant type. Near AC.
422.31- Appliances shalll have a disconnecting means. 110.25 lockouts acceptable. Oven, dishwasher, range hood.
440.11- Furnace shall have a manual disconnecting means.
ELE19-00750 Final3/8/20193/8/20193/8/2019 11:52:46 AMPPASS
Clerical issue on issued state of permit.
Final ok
ELE19-00750 Final3/7/20193/8/20193/8/2019 11:26:47 AMAFAIL
Job is ready to go homeowner will give access have a great weekend Phone #: ###-#### Inspection requested via web by TRENT Swaim Building permit has not been issued. Unable to inspect until BLD is issued. Recall when ready. Called contact.
ELE19-00678 Rough-In Permanent Service3/7/20193/8/20193/8/2019 10:58:16 AMAPASS
Phone #: ###-#### Inspection requested via web by shane miller
Service only p/s o/h n ok
ELE19-00198 Final3/7/20193/8/20193/8/2019 10:34:34 AMAFAIL
Phone #: ###-#### Inspection requested via web by Greg Traudt
210.52(C)- Pantry counter top area shall have receptacle outlets installed so that no point measured along wall line horizontally is more than 24" from a receptacle outlet.
ELE19-00631 Electrical Rough-In3/7/20193/8/20193/8/2019 9:13:57 AMAPASS
Please call Bob at ###-#### first thing in the morning. Thanks Phone #: ###-#### Inspection requested via web by Kerri Hamilton
North east corner under slab rough in ok cover
ELE19-00826 Final3/8/20193/8/20193/8/2019 12:00:00 AMPDONE
call owner at ###-#### for access Phone #: ###-#### >> Inspection requested via web by Brandon Winters