Inspections for the day of: Thursday, March 9, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorForrest France
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR05-00428 INSP-Final Inspection3/8/20063/9/20063/9/2006 6:40:54 PMPDEFR
No time for this inspection today, to be rescheduled per conversation with contractor for 3/10 in the am.
BLD05-03249 FIRE-Final Inspection3/9/20063/9/20063/9/2006 4:40:50 PMPDEFR
Duplicate inspection request.
BLD05-03248 FIRE-Final Inspection3/9/20063/9/20063/9/2006 4:31:59 PMPDEFR
Duplicate inspection request.
BLD05-03152 FIRE-Final Inspection3/9/20063/9/20063/9/2006 4:31:22 PMPPASS
Required corrections have been made, fire life safety passed inspection. Patio gate hardware has not been installed, however data was supplied to indicate the type installed is approved.
FIR05-00695 INSP-Final Inspection3/2/20063/9/20063/9/2006 4:27:00 PMAFAIL
Several monitoring points on the fire sprinkler system are not in condition to be tested including the dry systems (air compressors are not set), wet system flow (drain issues), standpipe tampers (closed for hydro test), need to provide proper SD coverage for the generator room as device is overspaced, provide visual notification in the generator room as the proper dB cannot be acheived, provide notification for the HC parking spot on ground level. No test of the elevator as access not available, FJ in stair 2 is not installed. Partial test only of the ground level alarm system today, plans will require resubmittals reflecting all changes, condition of the job prevents completion of testing for approval.
FIR05-00425 INSP-Sprinkler Rough-in/Hydro3/3/20063/9/20063/9/2006 4:07:27 PMAFAIL
Several c/n items from the previous day's inspections have not been completed including installation of the aux. tank valves, lock at the fuel line valve, repaired stop button at controller, flow chart data, controller monitoring of fuel levels per NFPA 20 2003 11.4.5.7 and 12.4.1.3 (11). Need to finish branch line above the tank at mech. room, install heads with wrench and NFPA 25 in the head box, install air compressors and re-set dry system air values, installation/inspection tags on the riser.
FIR05-00425 INSP-Sprinkler Rough-in/Hydro3/8/20063/9/20063/9/2006 3:48:57 PMPFAIL
Hydrostatic test of the standpipes in stair 1 and 2 failed due to pressures below 200 psi at several levels.
BLD04-02303 FIRE-Final Inspection3/8/20063/9/20063/9/2006 11:46:31 AMAFAIL
Lower the mounting height of the provided fire extinguisher to no higher than 48" AFF, post building address numbers as indicated in fire code review notes, provide approved hardware at the main entry/exit doors as discussed and reviewed on plan notes (remove door knob, manual thumbturns, provide keyed locking hardware and signage, single action hardware installed).
BLD06-00035 FIRE-Final Inspection3/8/20063/9/20063/9/2006 9:17:51 AMPCANC
mike Note: fire alarm/sprinklers to meet at 3:00 pm; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Marsha Smylie
FIR06-00114 INSP-Alarm Testing3/8/20063/9/20063/9/2006 9:16:43 AMPCANC
mike Note: fire alarm/sprinklers to meet at 3:00 pm; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Marsha Smylie
FIR06-00080 INSP-Final Inspection3/8/20063/9/20063/9/2006 9:16:12 AMPCANC
mike Note: fire alarm/sprinklers to meet at 3:00 pm; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Marsha Smylie
FIR05-00193 INSP-Final Inspection3/8/20063/9/20063/9/2006 9:09:24 AMAFAIL
One a/v in the "Varsity Grill" is non-functional, need to test the EOL at this location, address the required corrections for the concourse B as discussed, previous c/n items have been completed.
BLD06-00187 FIRE-Alarm Testing3/7/20063/9/20063/7/2006 12:00:00 AMACANC
Forrest, This again is for a life safety final; Phone #: ###-#### Internet Inspection Request from: Troy Mechsner///Cancel per Troy because incomplete 3-7-06 eus
FIR05-00757 INSP-Final Inspection3/7/20063/9/20063/7/2006 12:00:00 AMACANC
Forrest, This is another alarm inspection; Phone #: ###-#### Internet Inspection Request from: Troy Mechsner///Cancel per Troy because incomplete 3-7-06 eus