ELE13-00310
| ELE-Aging Inspection | 3/9/2016 | 3/9/2016 | 3/14/2016 10:29:32 AM | | CANC |
|
|
too busy
|
GCE15-00158
| GCE-Final | 3/9/2016 | 3/9/2016 | 3/9/2016 3:09:46 PM | P | PASS |
|
|
###-#### - code: 2727 corrections fixed final ok
|
GCE15-00157
| GCE-Final | 3/9/2016 | 3/9/2016 | 3/9/2016 3:08:32 PM | P | PASS |
|
|
###-#### - code: 2727 corrections fixed final ok
|
GCE15-00156
| GCE-Final | 3/9/2016 | 3/9/2016 | 3/9/2016 3:07:43 PM | P | PASS |
|
|
###-#### - code: 2727 corrections fixed final ok
|
ELE15-02697
| Electrical Rough-In | 3/9/2016 | 3/9/2016 | 3/9/2016 2:11:43 PM | P | PASS |
|
|
''drop'' ceiling inspection for first floor hallway running east-west Comtact: Ryan ###-#### Please schedule for as late in the afternoon as possible. Phone #: ###-#### Inspection requested via web by Tracy Robertson down hallway /janitors closet/electrical room and 2nd floor laundry/electrical cielings ok cover
|
ELE16-00724
| Rough-In Permanent Service | 3/9/2016 | 3/9/2016 | 3/9/2016 1:38:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman rough-in ok cover p/s u/g n ok
|
ELE16-00061
| Final | 3/9/2016 | 3/9/2016 | 3/9/2016 1:25:42 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Lars Johnson 422.30 disconnect or a listed lockout required for hot water heater Boise City Ordinance at least 50% of lighting shall be energy efficient
|
ELE16-00472
| Electrical Rough-In | 3/9/2016 | 3/9/2016 | 3/9/2016 1:01:31 PM | P | PASS |
|
|
Ceiling Insp. Phone #: ###-#### Inspection requested via web by John VanZandt correction fixed cielings ok cover
|
ELE15-03642
| Electrical Rough-In | 3/9/2016 | 3/9/2016 | 3/9/2016 12:42:16 PM | P | PASS |
|
|
electrical floor heat in master bathroom Phone #: ###-#### Inspection requested via web by steve sellers master floor heat ok cover
|
ELE15-03858
| Permanent Service | 3/9/2016 | 3/9/2016 | 3/9/2016 12:28:01 PM | P | PASS |
|
|
Ryan Barnes Phone #: ###-#### Inspection requested via web by Kerri Hamilton 1200 amp p/s u/g n ok
|
ELE16-00329
| Electrical Rough-In | 3/8/2016 | 3/9/2016 | 3/9/2016 12:11:12 PM | P | PASS |
|
|
Cover Phone #: ###-#### Inspection requested via web by Kerri Hamilton 4th floor cielings ok cover
|
ELE16-00633
| Electrical Rough-In | 3/8/2016 | 3/9/2016 | 3/9/2016 11:02:10 AM | A | PASS |
|
|
Underground inspection back of house for feeder conduits. Phone #: ###-#### Inspection requested via web by David Mackey underground to remote panels ok cover
|
ELE16-00699
| Permanent Service | 3/8/2016 | 3/9/2016 | 3/9/2016 10:31:04 AM | A | PASS |
|
|
Permanent Service Phone #: ###-#### Inspection requested via web by Brandon Winters p/s u/g n ok
|
ELE16-00733
| Rough-In Permanent Service | 3/9/2016 | 3/9/2016 | 3/9/2016 10:06:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk rough-in ok cover p/s u/g n ok
|
ELE16-00729
| Rough-In Permanent Service | 3/8/2016 | 3/9/2016 | 3/9/2016 9:37:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot detached garage ok cover p/s o/h n ok
|
ELE16-00504
| Final | 3/9/2016 | 3/9/2016 | 3/9/2016 8:54:45 AM | A | PASS |
|
|
I only am doing service on shop is completed and inspected --Close out Phone #: ###-#### Inspection requested via web by Therrin Robertson service on shop only. final ok
|
ELE16-00755
| Rough-In Permanent Service | 3/9/2016 | 3/9/2016 | 3/9/2016 8:53:27 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough-in ok cover p/s u/g n ok
|