MEC17-05498
| Pressure Test | 3/9/2018 | 3/9/2018 | 3/9/2018 4:16:24 PM | P | FAIL |
|
|
Gas line pressure test Phone #: ###-#### Inspection requested via web by Ted Dumont- 20lb gas pass underground- need to install 18 gauge yellow tracer wire for underground piping
|
MEC17-05418
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 3:52:05 PM | P | PASS |
|
|
door around back Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP
|
MEC18-01076
| Final | 3/7/2018 | 3/9/2018 | 3/9/2018 3:34:23 PM | P | NH |
|
|
PM. Please call on way. Dave ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss- no one home- no access-
|
MEC18-01090
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 3:18:26 PM | P | PASS |
|
|
ready, please call Rob ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace co ok
|
MEC18-01030
| Rough-in | 3/8/2018 | 3/9/2018 | 3/9/2018 3:08:35 PM | P | FAIL |
|
|
Rough in Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need approved ACCA report onsite- fireplace firestop needs plastic reattached and sealed up so can not come into contact with fireplace- b vent 2nd floor needs framed out and firestop put in at ceiling with insulation shield to fire stop- crawl needs completed- 6" fresh can not come from return air can needs to tie in before register- need to fix rips and tears on armaflex in crawl- b vent insulation shield in garage needs 1" clearance and secured- left correction notice front window
|
MEC18-01030
| Pressure Test | 3/8/2018 | 3/9/2018 | 3/9/2018 2:54:38 PM | P | PASS |
|
|
Pressure witness Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pass
|
MEC18-00914
| Conference | 3/9/2018 | 3/9/2018 | 3/9/2018 2:28:14 PM | P | PASS |
|
|
Requesting inspection for Exhaust System above hard lid.
Contact: Dave Godfrey Phone #: ###-#### Inspection requested via web by Melissa Kaae- R/I and seal on bathrooms ok for hard lids- PVC that plumber ran will need changed out to approved plenum rated material before cover
|
MEC18-01099
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 2:06:04 PM | P | PASS |
|
|
Should be ready after 1 today to inpect Inspection requested via web by Margie Rowe- electric furnace heat pump co ok
|
MEC17-05521
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 1:45:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP- final ok
|
MEC17-03795
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 1:12:42 PM | P | PASS |
|
|
Matt is contact. Thanks Phone #: ###-#### Inspection requested via web by Nicholas Paige- final ok
|
MEC18-01046
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 11:49:15 AM | A | PASS |
|
|
|
MEC18-01046
| Pressure Test | 3/6/2018 | 3/9/2018 | 3/9/2018 11:48:39 AM | P | PASS |
|
|
INSTALLER MIGUEL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- co installed
|
MEC17-02833
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 11:37:12 AM | P | PASS |
|
|
Call when you are on the way so we can meet you there with a ladder Phone #: ###-#### Inspection requested via web by Dan McFate- final ok
|
MEC18-00993
| Pressure Test | 3/9/2018 | 3/9/2018 | 3/9/2018 11:25:11 AM | P | PASS |
|
|
this is the installers # he will be there for pressure test please call when on the way Phone #: ###-#### Inspection requested via web by Marisa Hone- 20lb gas pass- 5lb flue pass
|
MEC18-01022
| Rough-in | 3/9/2018 | 3/9/2018 | 3/9/2018 11:13:07 AM | P | PASS |
|
|
Reinspection Inspection requested via web by Devony Bullard- R/I ok
|
MEC18-01022
| Pressure Test | 3/9/2018 | 3/9/2018 | 3/9/2018 11:12:47 AM | P | PASS |
|
|
re -inspection Inspection requested via web by Devony Bullard- 20lb gas pass
|
MEC17-05763
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 10:53:28 AM | A | FAIL |
|
|
Please contact Mike for access: ###-#### or ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello- need air balance report onsite- could not find one
|
MEC18-00915
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 10:31:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ron Arnold- electric furnace heat pump ok
|
MEC18-00808
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 9:56:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- Furnace co ok
|
MEC18-00943
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 9:28:58 AM | A | FAIL |
|
|
Mike-pleae call 30 minutes prior Phone #: ###-####- flue not holding pressure- need CO detector/s installed- need 30 amp fuses in ac disconnect- uv protection on lineset
|
MEC18-00943
| Pressure Test | 3/9/2018 | 3/9/2018 | 3/9/2018 9:27:56 AM | A | FAIL |
|
|
Mike-pleae call 30 minutes prior Phone #: ###-####- flue not holding pressure
|
MEC18-01022
| Rough-in | 3/8/2018 | 3/9/2018 | 3/9/2018 8:43:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- dryer vent needs to be in wall incloset and taped- notice in windows
|
MEC18-01022
| Pressure Test | 3/8/2018 | 3/9/2018 | 3/9/2018 8:39:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- gauge wont zero out
|
MEC18-01020
| Rough-in | 3/8/2018 | 3/9/2018 | 3/9/2018 8:38:54 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- R/I ok
|
MEC18-01020
| Pressure Test | 3/8/2018 | 3/9/2018 | 3/9/2018 8:38:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- 20lb gas pass
|
MEC17-00496
| Mec-Aging Inspection | 3/9/2018 | 3/9/2018 | 3/9/2018 8:02:39 AM | | PASS |
|
|
|
MEC17-00496
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 8:02:28 AM | A | PASS |
|
|
Alan passed this on aging- should of finaled out
|