ELE18-00878
| Permanent Service | 3/9/2018 | 3/9/2018 | 3/9/2018 3:13:32 PM | P | PASS |
|
|
service change...p/s u/g reconnect ok
|
ELE18-00212
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 2:44:44 PM | P | PASS |
|
|
Danny Phone #: ###-####...ok to final
|
ELE17-04175
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 2:36:16 PM | P | PART |
|
|
LATE // WES Phone #: ###-####...building complete, parking lot lights...seal offs for fuel and panels completed for full final...temp occupency ok
|
ELE17-04175
| Permanent Service | 3/9/2018 | 3/9/2018 | 3/9/2018 2:34:29 PM | P | PASS |
|
|
LATE // WES Phone #: ###-####...p/s for street light pedestal...ok to connect
|
ELE17-03003
| Permanent Service | 3/8/2018 | 3/9/2018 | 3/9/2018 1:51:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cris flores...p/s reconnect ok
|
ELE18-00897
| Permanent Service | 3/8/2018 | 3/9/2018 | 3/9/2018 1:24:03 PM | P | PASS |
|
|
starting panel change in the morning should be close to wrapped up by noon Phone #: ###-#### Inspection requested via web by Jay Hutchison...p/s u/g reconnect ok
|
ELE18-00739
| Rough-In Permanent Service | 3/9/2018 | 3/9/2018 | 3/9/2018 12:49:02 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ben Archibald....rough ok to cover...p/s u/g new ok
|
ELE18-00740
| Rough-In Permanent Service | 3/9/2018 | 3/9/2018 | 3/9/2018 12:47:44 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ben Archibald...rough ok to cover...p/s u/g new ok
|
ELE17-02649
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 11:48:36 AM | A | PART |
|
|
Partial final, contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell....partial final...rooms as marked on plans
|
ELE17-02649
| Electrical Rough-In | 3/8/2018 | 3/9/2018 | 3/9/2018 11:47:29 AM | A | PASS |
|
|
Ceiling inspection contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell....ceiling ok as marked on plans
|
ELE18-00889
| Final | 3/9/2018 | 3/9/2018 | 3/9/2018 10:23:33 AM | A | PASS |
|
|
Behind Cliffs safe, r/I for retrofit Anytime a/m or p/m works, I''ll be there all day. Please call when at front door. Thanks Phone #: ###-#### Inspection requested via web by Rex Boyles...job complete...ok to final
|
ELE18-00889
| Electrical Rough-In | 3/8/2018 | 3/9/2018 | 3/9/2018 10:23:07 AM | A | PASS |
|
|
Behind Cliffs safe, r/I for retrofit Anytime a/m or p/m works, I''ll be there all day. Please call when at front door. Thanks Phone #: ###-#### Inspection requested via web by Rex Boyles...replacing full fixture...UL listing verified
|
ELE18-00646
| Rough-In Permanent Service | 3/9/2018 | 3/9/2018 | 3/9/2018 9:57:27 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...rough ok to cover...p/s u/g new ok
|
ELE18-00282
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 9:25:13 AM | A | FAIL |
|
|
Please contact homeowner when on way Ryan Brushey ###-#### Todd ###-#### Phone #: ###-#### Inspection requested via web by Kendra Lanham...D/W needs installed-hardwired, 2 outlets on kitchen counter not GFI protected, 1 outlet in living room reverse polarity
|
ELE17-01625
| Final | 3/8/2018 | 3/9/2018 | 3/9/2018 8:24:54 AM | A | PASS |
|
|
first inspection 8:15 Lance ###-####...ok to final...homeowner to put metal purgulla over tub and will bond to tub
|