FIR08-00255
| INSP-Final Inspection | 3/27/2009 | 3/27/2009 | | P | |
|
|
Contact Rafe Phone#: ###-####
|
BLD06-02303
| FIRE-Hydro test above ground | 4/1/2009 | 4/1/2009 | 4/2/2009 2:08:45 PM | P | PART |
|
|
Hydrostatic retesting for the 14th floor completed, concluded satisfactory 24 hr. air test for the 3rd and 4th floor dry systems.
|
BLD09-00396
| FIRE-Final Inspection | 4/1/2009 | 4/1/2009 | 4/1/2009 4:13:13 PM | P | PASS |
|
|
Need to provide approved hardware at the back exit door or blank the exit sign prior to structural final approval.
|
BLD09-00074
| FIRE-Final Inspection | 4/1/2009 | 4/1/2009 | 4/1/2009 4:07:36 PM | P | PASS |
|
|
Fire life safety inspection completed acceptable.
|
FIR09-00143
| INSP-Final Inspection | 4/1/2009 | 4/1/2009 | 4/1/2009 3:29:24 PM | P | PASS |
|
|
Scope of fire sprinkler work passed inspection, field mods. okayed, permit finaled.
|
FIR08-00766
| INSP-Sprinkler Rough-in/Hydro | 3/31/2009 | 4/1/2009 | 4/1/2009 3:04:04 PM | P | PART |
|
|
Hydrostatic testing for UG supply lead in piping service to the truck return and maintenance buildings each completed satisfactory, maint. building service okayed within allowable leakage amounts per NFPA 13.
|
FIR08-00366
| INSP-Final Inspection | 3/31/2009 | 4/1/2009 | 4/1/2009 2:59:21 PM | A | NR |
|
|
Need to provide reset key to facilitate elevator recall testing, discussed firemans hat illumination per review comments.
|
BLD09-00301
| FIRE-Final Inspection | 3/31/2009 | 4/1/2009 | 4/1/2009 12:53:28 PM | A | PART |
|
|
See red-lines on plans for rack installation okayed to date.
|
BLD09-00074
| FIRE-Final Inspection | 3/31/2009 | 4/1/2009 | 4/1/2009 12:43:20 PM | A | NR |
|
|
Project related fire sprinkler permit work is not ready for final, noted one overspaced head at the kitchen area due to relocated wall. Remainder of life safety items inspected okayed including fire alarm and type one hood.
|
FIR09-00140
| INSP-Final Inspection | 4/1/2009 | 4/1/2009 | 4/1/2009 12:40:18 PM | P | PASS |
|
|
Scope of fire alarm work passed field testing, permit finaled.
|
FIR09-00118
| INSP-Final Inspection | 3/31/2009 | 4/1/2009 | 4/1/2009 12:39:10 PM | A | PASS |
|
|
Hood suppression system operated correctly under test conditions.
|
FIR08-00834
| FIR-Aging Inspection | 4/1/2009 | 4/1/2009 | 4/1/2009 10:57:06 AM | | DONE |
|
|
Work in progress, construction underway.
|
FIR09-00140
| INSP-Alarm Testing | 3/31/2009 | 4/1/2009 | 4/1/2009 12:00:00 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 3/31/2009 at 11:31:58 AM. Contact: ###-####.
|