ELE15-00765
| Permanent Service | 3/30/2015 | 4/1/2015 | 4/1/2015 3:26:51 PM | P | PASS |
|
|
Jake will be on site ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok
|
ELE15-00765
| Electrical Rough-In | 4/1/2015 | 4/1/2015 | 4/1/2015 3:25:10 PM | P | FAIL |
|
|
Jake will be on site ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Due to previous work performed without pulling permits wiring in overhead walkway and carport shall be replaced with wiring method listed for area. Will check after 7 working days 4/10/15 to ensure steps are being taken to correct illegal installation. If ignored steps will be taken to disconnect power until corrected. Section 4-05-32 CODE VIOLATION NOT TO BE RETAINED When altering a pre-existing electrical wire, equipment, apparatus or fixture, or adding any new wiring, the existing electrical wiring in close proximity shall be in accordance with the present code. (6338, Added, 08/03/2004) 334.12 Uses Not Permitted. (B) Types NM and NMS. Types NM and NMS cables shall not be used under the following conditions or in the following locations: (4) In wet or damp locations 334.15 Exposed Work. In exposed work, except as provided in 300.11(A), cable shall be installed as specified in 334.15 (B) Protection from Physical Damage.
|
GCE15-00049
| GCE-Final | 4/1/2015 | 4/1/2015 | 4/1/2015 2:50:32 PM | P | PASS |
|
|
Mike ###-#### - requested 1hr. call ahead Ballasts, lamps, and disconnecting means. UL listing confirmed. Final ok
|
GCE15-00048
| GCE-Final | 4/1/2015 | 4/1/2015 | 4/1/2015 2:07:59 PM | P | NH |
|
|
Contractor ###-#### No answer at door, left message with contractor no return phone call, must reschedule
|
ELE15-00852
| Final | 3/31/2015 | 4/1/2015 | 4/1/2015 1:59:11 PM | P | PASS |
|
|
200amp Service Change Phone #: ###-#### Inspection requested via web by Andy Rose Final ok
|
ELE15-00852
| Permanent Service | 4/1/2015 | 4/1/2015 | 4/1/2015 1:40:27 PM | P | PASS |
|
|
200amp Service Change Phone #: ###-#### Inspection requested via web by Andy Rose Feed from power company to short to reach lugs. p/s u/g rec ok
|
ELE14-03385
| Final | 4/1/2015 | 4/1/2015 | 4/1/2015 1:29:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Final ok
|
ELE15-00804
| Electrical Rough-In | 4/1/2015 | 4/1/2015 | 4/1/2015 1:07:20 PM | P | PASS |
|
|
Bob Phone #: ###-#### Room east side of house rough in ok cover
|
ELE15-00674
| Rough-In Permanent Service | 4/1/2015 | 4/1/2015 | 4/1/2015 12:43:58 PM | P | PASS |
|
|
cody is the contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
ELE15-00844
| Permanent Service | 3/31/2015 | 4/1/2015 | 4/1/2015 12:06:29 PM | P | PASS |
|
|
Please contact Jordan at the above number if you have any questions Phone #: ###-#### Inspection requested via web by Louis Keller 310.15(B)(7)- Shall fuse down sub feed due to SER in contact with insulation to garage panel. p/s u/g n ok
|
ELE15-00843
| Electrical Rough-In | 3/31/2015 | 4/1/2015 | 4/1/2015 11:31:22 AM | A | PASS |
|
|
Milenko Phone #: ###-#### Changing ballasts, lamps and adding disconnecting means. UL listing confirmed. Rough in ok
|
ELE15-00847
| Electrical Rough-In | 3/31/2015 | 4/1/2015 | 4/1/2015 10:34:58 AM | A | PASS |
|
|
Potting, Bonding and Underground Inspection Phone #: ###-#### Inspection requested via web by Louis Keller 4 corners, cover, light fixture, potting and underground rough in ok cover
|
ELE15-00854
| Final | 3/31/2015 | 4/1/2015 | 4/1/2015 10:03:38 AM | A | NH |
|
|
please contact homeowner for access @ ###-#### Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON AC check out ok no access to house for furnace, no answer at door and left message with number provided.
|
ELE15-00834
| Electrical Rough-In | 3/30/2015 | 4/1/2015 | 4/1/2015 9:40:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Fletcher Rewire exersize room for new door location and new door in garage. Rough in ok cover
|
ELE15-00779
| Final | 3/31/2015 | 4/1/2015 | 4/1/2015 9:31:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kendra Lanham Final ok
|
ELE15-00841
| Rough-In Permanent Service | 3/31/2015 | 4/1/2015 | 4/1/2015 8:13:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Rough in ok cover p/s u/g n ok
|