Inspections for the day of: Friday, April 1, 2016.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02226 ELE-Aging Inspection4/1/20164/1/20164/5/2016 12:13:55 PM CANC
too busy
ELE13-01600 ELE-Aging Inspection4/1/20164/1/20164/5/2016 12:13:37 PM CANC
too busy
ELE15-02697 Final4/1/20164/1/20164/1/2016 3:56:16 PMPPASS
final inspect for units 201/202/207/209/217/101/102/103/104/105/106/107/109/117/common area offices first floor, first floor corridor riser room and entire building final. Phone #: ###-#### Inspection requested via web by Tracy Robertson remaining units 201,202,207,209,217,101,102,103,104,105,106,107,109,117 first floor corridors, baths, storage,library,common areas, electrical room, fire riser room and exterior of building, and halls final ok
ELE16-00776 Final3/31/20164/1/20164/1/2016 1:43:36 PMPPASS
Call George to meet at job site Phone #: ###-#### Inspection requested via web by Thaniel Bishop solar array final ok
ELE16-00711 Electrical Rough-In4/1/20164/1/20164/1/2016 1:19:52 PMPPASS
Eddy Phone #: ###-####5 kitchen, laundry, upstairs master bed and bath rough-in ok cover
ELE16-00964 Permanent Service4/1/20164/1/20164/1/2016 12:55:16 PMPCANC
Phone #: ###-#### Inspection requested via web by Randy Fletcher needed rough-in
ELE16-00964 Final4/1/20164/1/20164/1/2016 12:54:50 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Fletcher 240.24 no OCPD shall be higher then 6'-7" contractor will build a platform to fix this issue
ELE16-01005 Final4/1/20164/1/20164/1/2016 12:31:39 PMPFAIL
Greg Phone #: ###-#### 210.50 walls greater then 24" shall have a receptacle (buried behind sheetrock in up west bed)
ELE15-03690 Final4/1/20164/1/20164/1/2016 12:30:15 PMPPASS
Inspection requested via web by Terry Scott this was for rough-in only, homeowner has pulled permit ele16-01005 for trim and final and will resume responsibility for work.
ELE15-03873 Electrical Rough-In4/1/20164/1/20164/1/2016 11:52:46 AMPNR
equipotential grid Phone #: ###-#### Inspection requested via web by Lee VanSchoiack bond wire not installed
ELE16-01012 Rough-In Permanent Service4/1/20164/1/20164/1/2016 11:41:39 AMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough-in ok cover p/s u/g rec ok
ELE16-00968 Rough-In Permanent Service3/31/20164/1/20164/1/2016 10:35:24 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk rough-in p/s u/g n ok
ELE16-00489 Electrical Rough-In3/31/20164/1/20164/1/2016 10:29:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Dean Gernaat kitchen remodel final ok
ELE16-00554 Final3/31/20164/1/20164/1/2016 10:28:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Don Conley final on lighting addition ok
ELE16-00699 Permanent Service3/31/20164/1/20164/1/2016 10:14:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Brandon Winters needed final
ELE16-00699 Final4/1/20164/1/20164/1/2016 10:13:41 AMPPASS
Phone #: ###-#### Inspection requested via web by Brandon Winters service change final ok
ELE16-00110 Final4/1/20164/1/20164/1/2016 9:43:08 AMAPASS
corrections have been made Phone #: ###-#### Inspection requested via web by Shaun Kirkman corrections fixed final ok
ELE16-00907 Electrical Rough-In3/31/20164/1/20164/1/2016 9:22:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Don Conley kitchen remodel ok cover
ELE15-04113 Electrical Rough-In3/31/20164/1/20164/1/2016 8:55:36 AMAPASS
Floor heat utility and hall Phone #: ###-#### Inspection requested via web by John VanZandt utility and hall floor heat ok cover