Inspections for the day of: Friday, April 10, 2015.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM14-03047 PLM-Aging Inspection4/10/20154/10/20154/10/2015 4:54:16 PM PART
no call,s
PLM14-03052 PLM-Aging Inspection4/10/20154/10/20154/10/2015 4:52:14 PM PASS
PLM14-03052 DOC - Permit Finaled4/10/20154/10/20154/10/2015 4:51:45 PMPPASS
PLM15-01116 Water and/or Sewer4/10/20154/10/20154/10/2015 3:44:37 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Vicki Tallent
PLM15-01118 Water and/or Sewer4/10/20154/10/20154/10/2015 3:43:26 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Vicki Tallent
PLM14-00333 PLM-Aging Inspection4/10/20154/10/20154/10/2015 3:39:15 PM PART
under construction
PLM15-00697 Plumbing Rough-in4/10/20154/10/20154/10/2015 3:37:28 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Erin Whiting need to replace fernco coupling with an approved shielded band as noted in correction notice issued on 4/7/2015 at building drain and sewer connection in crawl other correction have been made test on DWV test ok correction notice on site contractor to recall when ready
PLM14-02890 Water and/or Sewer4/10/20154/10/20154/10/2015 2:55:52 PMPPART
Pete Phone #: ###-#### visual on water line ok still need to test called contractor will recall when ready
PLM15-01136 Water and/or Sewer4/10/20154/10/20154/10/2015 2:54:37 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Scott Wickstrom
PLM15-01136 DOC - Permit Finaled4/10/20154/10/20154/10/2015 2:54:07 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Scott Wickstrom
PLM15-01112 Groundwork4/9/20154/10/20154/10/2015 1:51:08 PMPPASS
MICHAEL IS THE JOB CONTACT ###-#### Phone #: ###-#### >> Inspection requested via web by BECCA DUMMER
PLM14-03499 Plumbing Rough-in4/10/20154/10/20154/10/2015 1:29:16 PMPCANC
1st floor rough-in wall inspection is complete Phone #: ###-#### >> Inspection requested via web by Travis Baker 1st floor in wall rough-in test ok ok to cover
PLM15-01114 Sprinkler (Final)4/9/20154/10/20154/10/2015 1:05:37 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Darrell Roark
PLM15-01130 Plumbing Rough-in4/10/20154/10/20154/10/2015 12:47:05 PMPFAIL
JOB # 17898. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes 906.2 vent termination. vent shall not terminate not less than 10 feet from openable window. need to move two inch on east side of building correction notice on site contractor to recall when ready