Inspections for the day of: Wednesday, April 10, 2019.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-00998 ELE-Aging Inspection4/10/20194/10/20194/11/2019 10:35:04 AM DONE
Left message for owner. No activity.
ELE17-01995 Final4/10/20194/10/20194/10/2019 2:25:00 PMPPASS
Phone #: ###-#### Inspection requested via web by chris hopkins final ok
ELE17-01995 Electrical Rough-In4/10/20194/10/20194/10/2019 2:24:48 PMPPASS
Phone #: ###-#### Inspection requested via web by chris hopkins rough in ok
ELE18-00219 Final4/10/20194/10/20194/10/2019 2:19:41 PMPPASS
does not have to be done on this date. Phone #: ###-#### Inspection requested via web by chris hopkins final ok
ELE17-01995 Electrical Rough-In4/10/20194/10/20194/10/2019 2:09:31 PMPPASS
Phone #: ###-#### Inspection requested via web by chris hopkins rough in ok
ELE19-00337 Electrical Rough-In4/10/20194/10/20194/10/2019 1:55:42 PMPFAIL
We need a 1PM inspection Phone #: ###-#### Inspection requested via web by Brecklee Brown No body onsite recall
ELE19-00103 Final4/10/20194/10/20194/10/2019 1:41:52 PMPFAIL
Phone #: ###-#### Inspection requested via web by Andy Derrick 410.16 Luminaire types not permitted. Incondescent luminaires with open or partially enclosed lamps shall not be permited.(1 can master bath closet and 2 cans front bed closet.) 314.20 Flush mounted instalation. Boxes set back more than 1/4in shall have extension. (washer dryer receps)
ELE19-01269 Permanent Service4/10/20194/10/20194/10/2019 1:07:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Dustin Kuester Corrections made p/s o/h rec/n ok
ELE19-01209 Electrical Rough-In4/10/20194/10/20194/10/2019 12:12:02 PMPPASS
Kathy Phone #: ###-#### Corrections made Laundry, mud and kitchen ok to cover
ELE17-00745 Final4/5/20194/10/20194/10/2019 12:05:48 PMPPASS
Please contact homeowner prior to arrival. ###-####. Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
ELE19-01130 Permanent Service4/10/20194/10/20194/10/2019 11:52:15 AMPPASS
Phone #: ###-#### Inspection requested via web by Ryan Wake p/s u/g n ok
ELE19-00362 Final4/10/20194/10/20194/10/2019 11:49:45 AMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
ELE19-01277 Electrical Rough-In4/10/20194/10/20194/10/2019 11:07:08 AMAPASS
Please inspect soffit cans for cover, late morning if possible please. Phone #: ###-#### Inspection requested via web by Robert Schroder Soffits only ok to cover
ELE19-00771 Electrical Rough-In4/9/20194/10/20194/10/2019 10:29:50 AMAPASS
Andy Chambers is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce Discussed GFCI requirments for kitchen. Half wall in Kitchen only ok to cover
ELE19-01269 Permanent Service4/9/20194/10/20194/10/2019 9:59:31 AMAFAIL
If you need to get in the house the code is 7070
Thank you!
Dustin Phone #: ###-#### Inspection requested via web by Dustin Kuester 230.28B Service drop or overhead shall not be attached between wheather head and a coupling, where the coupling is above the last point of support..
ELE19-01209 Electrical Rough-In4/9/20194/10/20194/10/2019 9:38:26 AMAFAIL
ACCESS CODE 5237 Phone #: ###-#### Inspection requested via web by Eric Schroeder J boxes shall be accassable . (Burried jbox in new laundry room)
ELE19-01274 Rough-In Permanent Service4/9/20194/10/20194/10/2019 9:16:10 AMACANC
Hello, I would like to have the existing electrical Pedestal inspected, so that I can feed a sub-panel from it. ID Power is requesting an inspection, because there has not been a Meter installed in it for over a year. I did not want to proceed with the other work until I know the Pedestal is OK.

I did not plan on being there.

* The lot has a fence around it. There is a gate at the SE corner of the lot and it will be unlocked and slightly propped open. The Pedestal is on the N. side of the lot, in the middle of the fence line.

Thank you,
Lonnie
Phone #: ###-#### Inspection requested via web by Lonnie Sorichta
ELE19-01274 Electrical Rough-In4/10/20194/10/20194/10/2019 9:16:03 AMPPASS
Hello, I would like to have the existing electrical Pedestal inspected, so that I can feed a sub-panel from it. ID Power is requesting an inspection, because there has not been a Meter installed in it for over a year. I did not want to proceed with the other work until I know the Pedestal is OK.

I did not plan on being there.

* The lot has a fence around it. There is a gate at the SE corner of the lot and it will be unlocked and slightly propped open. The Pedestal is on the N. side of the lot, in the middle of the fence line.

Thank you,
Lonnie
Phone #: ###-#### Inspection requested via web by Lonnie Sorichta Pedistal is in good condition and is usable.
ELE19-01228 Final4/8/20194/10/20194/10/2019 8:48:17 AMAPASS
Jon Fivecoat is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Final ok
ELE19-01228 Electrical Rough-In4/10/20194/10/20194/10/2019 8:48:02 AMPPASS
Jon Fivecoat is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Transformer, low volt panel, and oven wiring Rough in ok
ELE19-01209 Final4/10/20194/10/20194/10/2019 12:00:00 AMPCANC
CLIENT SCHEADULE WRONG INSPECTION-
ACCESS CODE 5237 Phone #: ###-#### >> Inspection requested via web by Eric Schroeder