Inspections for the day of: Monday, April 11, 2005.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01050 Electrical Rough-In4/8/20054/11/20054/11/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 4/8/2005 at 11:53:56 AM. Contact: ###-####. ok to cover u/g for pipng around pool 4/11/2005 8:34:20 AM
ELE05-01182 Final4/8/20054/11/20054/11/2005 12:00:00 AMAPASS
Spa Final please; Phone #: ###-#### ok to final 4/11/2005 9:57:13 AM
ELE05-01139 Rough-In Permanent Service4/8/20054/11/20054/11/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 4/8/2005 at 2:52:26 PM. Contact: ###-####. ok to cover for conc encased electrode 4/11/2005 10:09:03 AM
ELE05-01197 Rough-In Permanent Service4/8/20054/11/20054/11/2005 12:00:00 AMAPASS
dino ###-#### called contr, left survey for add 2 recpts per 210.52 (A) (2). one by entry door and one in mbr. ric ok, p/s u/g n ok 4/11/2005 9:11:07 AM
ELE05-00696 Final4/8/20054/11/20054/11/2005 12:00:00 AMAFAIL
Thank you ; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left corr notice, 210.8 recpts in kitchen shall be gfci protected, 210.52(C)(1) recpts shall be placed so no point is over 24" along wall line, 352.30(A) rnc shall be supported within 3' of box BCC no code violations shall be retained. 4/11/2005 8:21:10 AM
ELE05-00717 Rough-In Permanent Service4/10/20054/11/20054/11/2005 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 4/10/2005 at 10:04:34 PM. Contact: ###-####. met with owner, outside ready, but he needs to provide ground lug inside at sub-panel 4/11/2005 3:48:29 PM
ELE04-03672 Rough-In Permanent Service4/11/20054/11/20054/11/2005 12:00:00 AMPCANC
re-inspection on service; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen called wrong address for insp 4/11/2005 4:39:48 PM
ELE05-01180 Electrical Rough-In4/11/20054/11/20054/11/2005 12:00:00 AMPPASS
jerry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore corrections made, ric ok 4/11/2005 12:16:05 PM
ELE05-01098 Electrical Rough-In4/11/20054/11/20054/11/2005 12:00:00 AMPFAIL
david; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called contr, left corr notice, 300.4(D) 1 1/4" shall be maintained from edge if framing members,250.148(B) ground connections in box shall be continuous, 210.52(B)(2) hood shall not be on small appliance ckt, 110.12(A) un-used openings shall be closed in range box, 210.52(A)(1) &(2) 6' receptacle spacing shall be maintained, 310.15(B)(6) feeders too small for 200A panel 4/11/2005 1:35:29 PM
ELE05-01040 Electrical Rough-In4/11/20054/11/20054/11/2005 12:00:00 AMPPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore walls downstairs only ok to cover. Called contr. Rest to be surface run. 4/11/2005 2:22:24 PM
ELE05-00717 Rough-In Permanent Service4/10/20054/11/20054/10/2005 10:01:29 PMACANC
Scheduled by a contractor via Hello! on 4/10/2005 at 9:58:48 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Apr 10 2005 10:01PM.