ELE17-01008
| Electrical Rough-In | 4/11/2017 | 4/11/2017 | 4/11/2017 12:52:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by mike brown media and dining room ok cover
|
ELE17-00617
| Electrical Rough-In | 4/11/2017 | 4/11/2017 | 4/11/2017 12:08:56 PM | P | PASS |
|
|
Al Phone #: ###-#### u/g from house to shop ok cover
|
ELE17-00169
| Final | 4/11/2017 | 4/11/2017 | 4/11/2017 11:07:26 AM | P | FAIL |
|
|
Access is "1969 Enter" Phone #: ###-#### Inspection requested via web by Paula Gratiot 110.3 Fix smoke in back bed thats hanging down 110.21 Reverse polarity in utility 210.8 All receptacles located within 6' of a sink shall have GFCI protection(utility) 406.4 All receptacles shall be tamper (pantry)
|
ELE17-01005
| Temporary Service | 4/10/2017 | 4/11/2017 | 4/11/2017 10:59:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon t/s u/g n ok
|
ELE17-00997
| Electrical Rough-In | 4/10/2017 | 4/11/2017 | 4/11/2017 10:34:47 AM | A | PASS |
|
|
Larry Phone #: ###-#### Room off carport only ok cover
|