Inspections for the day of: Tuesday, April 11, 2017.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01008 Electrical Rough-In4/11/20174/11/20174/11/2017 12:52:58 PMPPASS
Phone #: ###-#### Inspection requested via web by mike brown
media and dining room ok cover
ELE17-00617 Electrical Rough-In4/11/20174/11/20174/11/2017 12:08:56 PMPPASS
Al Phone #: ###-####
u/g from house to shop ok cover
ELE17-00169 Final4/11/20174/11/20174/11/2017 11:07:26 AMPFAIL
Access is "1969 Enter" Phone #: ###-#### Inspection requested via web by Paula Gratiot
110.3 Fix smoke in back bed thats hanging down
110.21 Reverse polarity in utility
210.8 All receptacles located within 6' of a sink shall have GFCI protection(utility)
406.4 All receptacles shall be tamper (pantry)
ELE17-01005 Temporary Service4/10/20174/11/20174/11/2017 10:59:14 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon
t/s u/g n ok
ELE17-00997 Electrical Rough-In4/10/20174/11/20174/11/2017 10:34:47 AMAPASS
Larry Phone #: ###-####
Room off carport only ok cover