ELE03-02916
| Final | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | NH |
|
|
8:30 am damon; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 4/11/2005 9:08:04 AM
Damon was a no-show 4/12/2005 8:28:37 AM
|
ELE04-04085
| Electrical Rough-In | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
dennis Note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
ELE05-01154
| Final | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
please contact Miles, thank you.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
|
ELE05-01186
| Rough-In Permanent Service | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
PLEASE TRY TO MAKE IT TODAY IF YOU CAN I CLICKED ON THE WRONG PERMIT AND WE NEED POWER TODAY IF POSSIBLE..SORRY AND THANKS PAT; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen
P/S O/H R OK 4/11/2005 2:19:58 PM
|
ELE05-01092
| Final | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
spr time clocks--bernice-- ###-#### --for arrowhead canyon
|
ELE05-00383
| Electrical Rough-In | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
ceiling cover rough-in, please contact Nick, thank you.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
|
ELE04-03996
| Final | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
wayne; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
ELE05-00587
| Final | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | NR |
|
|
Service Inspection ONLY; Phone #: ###-#### Internet Inspection Request from: Casey Sells
|
ELE05-00587
| Permanent Service | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
P/S U/G N Ok
|
ELE05-01092
| Permanent Service | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | A | PASS |
|
|
P/S U/G N Ok
|
ELE05-01202
| Electrical Rough-In | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | PART |
|
|
underground for hot tub ok
|
ELE03-03953
| Final | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | NH |
|
|
Scheduled by a contractor via Hello! on 4/12/2005 at 7:40:28 AM. Contact: ###-####.
no access called 4/12/2005 4:17:32 PM
|
ELE05-01185
| Final | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | FAIL |
|
|
We:1)wired 4 car lifts, 2)wired four 120 volt receptacles for trouble lights, 3)re-fed power to some existing receptacles in shop, 4)relocated an existing 40 amp 230 volt outlet approx 50 feet away, 5) wired air compressor.Owner will give you the tour.If you have any questions call Craig @ ###-####. Thanks!!!!Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
406.3(D) gfci protect receps. 4/12/2005 4:29:15 PM
|
ELE04-02485
| Electrical Rough-In | 4/12/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 4/12/2005 at 8:44:46 AM. Contact: ###-####.
210.52 Dwelling Unit Receptacle Outlets.
(A) General Provisions. In every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets shall be installed in accordance with the general provisions specified in 210.52(A)(1) through (A)(3).
(D) Bathrooms. In dwelling units, at least one wall receptacle outlet shall be installed in bathrooms within 900 mm (3 ft) of the outside edge of each basin.
This is the upstairs bathroom.
314.25 Covers and Canopies.
In completed installations, each box shall have a cover, faceplate, lampholder, or luminaire (fixture) canopy, except where the installation complies with 410.14(B). Can light in kitchen has no cover plate.
110.12 Mechanical Execution of Work.
(C) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated. 110.2 Approval.
The conductors and equipment required or permitted by this Code shall be acceptable only if approved,
and such approvals are based on tests and listings of testing laboratories.
Can lights in kitchen have listing instructions obliterated by texture spray.
200.7 Use of Insulation of a White or Gray Color or with Three Continuous White Stripes.
(C) Circuits of 50 Volts or More.
water heater white wire shall be reidentified
314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).
(C) Nonmetallic Boxes and Conduit Bodies. Nonmetallic boxes and conduit bodies shall be suitable for the lowest temperature-rated conductor entering the box. Where nonmetallic boxes and conduit bodies are used with open wiring or concealed knob-and-tube wiring, the conductors shall enter the box through individual holes. Where flexible tubing is used to enclose the conductors, the tubing shall extend from the last insulating support to not less than 6 mm (1/4 in.) inside the box and beyond any cable clamp. Where nonmetallic-sheathed cable or multiconductor Type UF cable is used, the sheath shall extend not less than 6 mm (1/4 in.) inside the box and beyond any cable clamp. In all instances, all permitted wiring methods shall be secured to the boxes. This is on the first floor by garage.
4/12/2005 3:44:29 PM
|
ELE05-01202
| Permanent Service | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
|
ELE05-01214
| Electrical Rough-In | 4/11/2005 | 4/12/2005 | 4/12/2005 12:00:00 AM | P | PASS |
|
|
Ready early in afternoon. Thanks!; Phone #: ###-#### Internet Inspection Request from: Heather Packer
|
ELE04-03867
| Electrical Rough-In | 4/7/2005 | 4/12/2005 | 4/8/2005 12:34:33 PM | P | CANC |
|
|
CONTACT: CASEY WILDE; Phone #: ###-#### Internet Inspection Request from: Deb McCoy Inspection cancelled from web by: Deb McCoy
|