ELE07-01276
| Temporary Service | 4/12/2007 | 4/12/2007 | 4/12/2007 4:45:32 PM | P | PASS |
|
|
Phone #: ###-#### t/s u/g n ok
|
ELE07-00120
| ELE-Aging Inspection | 4/12/2007 | 4/12/2007 | 4/12/2007 4:21:33 PM | | DONE |
|
|
suc, open type permit
|
ELE07-00118
| ELE-Aging Inspection | 4/12/2007 | 4/12/2007 | 4/12/2007 4:20:52 PM | | DONE |
|
|
suc, open type permit
|
ELE07-01217
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 4:18:56 PM | P | PASS |
|
|
bruce - late afternoon and pls call 30 min prior; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met contr, ric walls only ok
|
ELE07-00445
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 3:47:23 PM | P | PART |
|
|
Outside walls of the living room cover for master bedroom & closet only ###-#### Dennis ric ok as requested
|
ELE07-01270
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 3:13:45 PM | P | PASS |
|
|
tom - late afternoon please ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok, told to add recpt in 2' wall
|
ELE07-01196
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 2:18:53 PM | P | PASS |
|
|
This is a wall rough in. Phone #: ###-#### walls only ok to cover, called contr to fix address
|
ELE07-01287
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 1:46:27 PM | P | FAIL |
|
|
chad-- ###-#### --call 1st before insp called, left corr notice, nec 300.4(A)&(D) edge of bored holes and mc cable shall be 1 1/4" from edge of framing members, 330.30(B) mc cable shall be secured within 12" of box, 110.12(A) unused openings shall be closed, 300.6(A) mc cable shall be protected from corrosion if on copper warer pipe
|
ELE07-00872
| Final | 4/11/2007 | 4/12/2007 | 4/12/2007 1:10:57 PM | P | PASS |
|
|
electrician - Tom Wonacott Phone #: ###-#### corr made, ok to final
|
ELE07-01093
| Final | 4/11/2007 | 4/12/2007 | 4/12/2007 10:51:02 AM | A | PASS |
|
|
electrician - Kyle Sharp Phone #: ###-#### ok to final
|
ELE07-00194
| Electrical Rough-In | 4/12/2007 | 4/12/2007 | 4/12/2007 10:30:57 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 4/12/2007 at 6:59:56 AM. Contact: ###-####. north 1/2 first floor ceiling ok to cover, south offices of this area ok for t/o, need to check kitchen area and north most office recpts, no occ card to sign
|
ELE07-00682
| Permanent Service | 4/11/2007 | 4/12/2007 | 4/12/2007 9:49:45 AM | A | PASS |
|
|
Our man Steve will be there and reachable at ###-####. Phone #: ###-#### p/s, exst meter pak, n, ok
|
ELE07-01275
| Rough-In Permanent Service | 4/11/2007 | 4/12/2007 | 4/12/2007 9:15:24 AM | A | CANC |
|
|
home owner will be home from 8 am to 11 am Phone #: ###-#### see p/s for time
|
ELE07-01244
| Rough-In Permanent Service | 4/11/2007 | 4/12/2007 | 4/12/2007 9:11:23 AM | A | PASS |
|
|
Phone #: ###-#### walls and hard lids only ok to cover, p/s, exst meter pak, n, ok
|
ELE07-01275
| Permanent Service | 4/12/2007 | 4/12/2007 | 4/12/2007 8:42:07 AM | A | PASS |
|
|
home owner will be home from 8 am to 11 am Phone #: ###-#### p/s o/h rec ok
|
ELE06-00411
| Final | 4/11/2007 | 4/12/2007 | 4/12/2007 8:32:05 AM | A | PASS |
|
|
Rod; Phone #: ###-#### Internet Inspection Request from: Stacie Backus corr made, ok to final
|
ELE07-01269
| Electrical Rough-In | 4/11/2007 | 4/12/2007 | 4/12/2007 8:05:47 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/11/2007 at 2:02:28 PM. Contact: ###-####. ok to cover u/g from main switchgear to new bldg only
|
ELE06-03427
| Final | 4/11/2007 | 4/12/2007 | 4/11/2007 6:43:28 PM | A | CANC |
|
|
We put the cut sheets showing the UL listing for the floor boxes on the front entry vestibule window Phone #: ###-#### Inspection cancelled from web by: Jamie Winters
|