ELE12-01429
| ELE-Aging Inspection | 4/12/2017 | 4/12/2017 | 4/18/2017 3:02:34 PM | | PASS |
|
|
Still under construction
|
ELE12-02998
| ELE-Aging Inspection | 4/12/2017 | 4/12/2017 | 4/18/2017 2:55:20 PM | | PASS |
|
|
Waiting on contractor
|
ELE17-00115
| Electrical Rough-In | 4/12/2017 | 4/12/2017 | 4/12/2017 3:25:32 PM | P | PASS |
|
|
Ceiling Rough In inspection for Moffatt Thomas Contact Jon Novak Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Grid rough in ok cover
|
ELE17-00938
| Electrical Rough-In | 4/11/2017 | 4/12/2017 | 4/12/2017 3:15:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Area lighting being added. Supplied from restrooms to south 2 1" PVC conduits to pole lights at entrance to new area and several bollards thru out. East portion of underground rough in ok cover
|
ELE17-00975
| Electrical Rough-In | 4/12/2017 | 4/12/2017 | 4/12/2017 1:50:02 PM | P | PASS |
|
|
Kitchen remodel Rough in ok cover
|
ELE17-00034
| Electrical Rough-In | 4/11/2017 | 4/12/2017 | 4/12/2017 12:55:08 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by CHRIS CARMINE Underground on interior of shop rough in ok cover
|
MIS17-00112
| ELE-Conference | 4/12/2017 | 4/12/2017 | 4/12/2017 12:40:54 PM | P | DONE |
|
|
327 onsite to inspect detached building in rear of lot. Went to door for permission to access lot and owner escorted me thru house and noticed kitchen remodel of replacement of cabinets with some new wiring. Asked who performed work and he stated he did. I informed a permit is required and if he pulled 1 today additional fees would not be assessed. Answered all owners questions and at end of conversation he stated he would not pull permit if wall cover needed to be removed or if receptacles were required to be installed in tile backsplash. Wife would refuse these locations. 327 then created MIS and call 363 who is assigned to area.
|
ELE17-00994
| Final | 4/11/2017 | 4/12/2017 | 4/12/2017 10:40:22 AM | A | NR |
|
|
Paul Phone #: ###-#### Power not connected yet.
|
ELE17-00994
| Permanent Service | 4/12/2017 | 4/12/2017 | 4/12/2017 10:40:02 AM | P | PASS |
|
|
Paul Phone #: ###-#### p/s o/h n ok
|
ELE16-03138
| Final | 4/11/2017 | 4/12/2017 | 4/12/2017 9:56:14 AM | A | NR |
|
|
Tony Phone #: ###-#### Work yet to finish. See RI notes
|
ELE16-03138
| Electrical Rough-In | 4/11/2017 | 4/12/2017 | 4/12/2017 9:55:27 AM | A | FAIL |
|
|
Juile ###-#### Tony Phone #: ###-#### Homeowner requested inspections. All-star Electric has open permit ###-####. Electrical contractor only one to request inspections under permit purchased. 210.52- Door to be framed in at entrance to bedroom shall have a receptacle outlet located with in 6'. No point measured along floor line shall be greater than 6' fram a receptacle outlet. 300.15- All wiring shall terminate in a box with cover. Old AC location next to stairway outdoors and misc covers needed inside. 400.8- Flexible cords shall not pass thru doorway, walls, or ceiling. Relocate sump pump receptacle to inside room. 410.16- Luminaires located in closets and storage area shelves shall be totally enclosed type. New closet to be built in bed with 2 cans with open type and open lamp in storage area. 422.30- Water heater shall have a disconnecting means located with in sight. Lock out acceptable as per 110.25.
|