ELE05-04666
| ELE-Aging Inspection | 4/13/2006 | 4/13/2006 | 4/20/2006 8:53:17 AM | | PART |
|
|
called HP xray unit is supposed to be in sometime around the 1st of May
|
ELE05-04594
| ELE-Aging Inspection | 4/13/2006 | 4/13/2006 | 4/14/2006 3:48:52 PM | | PART |
|
|
stopped at site wsuc
|
ELE06-00073
| ELE-Aging Inspection | 4/13/2006 | 4/13/2006 | 4/14/2006 7:58:09 AM | | PART |
|
|
stopped at site wsuc
|
ELE06-01275
| Electrical Rough-In | 4/13/2006 | 4/13/2006 | 4/13/2006 4:50:48 PM | P | PART |
|
|
Justin -- ufer ground; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok
|
ELE06-00711
| Electrical Rough-In | 4/13/2006 | 4/13/2006 | 4/13/2006 4:36:08 PM | P | PART |
|
|
Todd -- wall cover; call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong 2nd floor as noted on prints ok
|
ELE06-01147
| Final | 4/13/2006 | 4/13/2006 | 4/13/2006 2:36:20 PM | P | PASS |
|
|
need final on cool ped for A/C. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok p/s u/g new
|
ELE06-01263
| Conference | 4/13/2006 | 4/13/2006 | 4/13/2006 1:49:40 PM | P | DONE |
|
|
mel; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|
ELE05-04417
| Electrical Rough-In | 4/13/2006 | 4/13/2006 | 4/13/2006 12:28:34 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 4/13/2006 at 7:30:04 AM. u/g inside for power and phone
|
ELE05-03919
| Final | 4/12/2006 | 4/13/2006 | 4/13/2006 11:52:20 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Randy Vail was done 04-12-06 by 412
|
ELE06-00223
| Final | 4/12/2006 | 4/13/2006 | 4/13/2006 11:46:46 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
|
ELE06-00186
| Final | 4/12/2006 | 4/13/2006 | 4/13/2006 11:46:29 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
|
ELE06-00031
| Final | 4/12/2006 | 4/13/2006 | 4/13/2006 11:46:11 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
|
ELE05-04623
| Final | 4/12/2006 | 4/13/2006 | 4/13/2006 11:46:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
|
ELE06-00901
| Rough-In Permanent Service | 4/12/2006 | 4/13/2006 | 4/13/2006 10:52:41 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr. called 210.52 needs outlet wall space fixed panel din rm slider, 300.4 nail plates, complete all makeup , protect panel
|
ELE06-01142
| Electrical Rough-In | 4/12/2006 | 4/13/2006 | 4/13/2006 10:08:20 AM | A | FAIL |
|
|
UNDERGROUND Internet Inspection Request from: Tyler Bowen corr do not cover called 352.26 over 360 degrees of bend in u/g to pool light and out in the yard
|
ELE05-04193
| Final | 4/13/2006 | 4/13/2006 | 4/13/2006 9:40:46 AM | A | FAIL |
|
|
Please call Brian Leavitt (builder) @###-#### before going over so access can be provided. thank you. Internet Inspection Request from: Paul Young corr. did not call, no number for electrical contractor 410.8 clearence closet under stairs, 314.16 box fill end of peninsular counter also protect romex, 210.52 needs outlet on kit circuit, fixed panel of slider over 6 ft
|
ELE06-01136
| Conference | 4/12/2006 | 4/13/2006 | 4/13/2006 8:46:48 AM | A | DONE |
|
|
###-#### - greg went over corrections with contractor
|