Inspections for the day of: Friday, April 13, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03567 Final4/13/20074/13/20074/13/2007 4:10:25 PMPPASS
sead ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, ok to final
ELE07-01287 Electrical Rough-In4/13/20074/13/20074/13/2007 3:37:52 PMPPASS
chad ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, ric upstairs only ok
ELE07-01307 Rough-In Permanent Service4/13/20074/13/20074/13/2007 3:00:41 PMPPASS
brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok, no u/g seen to garage
ELE07-01306 Final4/13/20074/13/20074/13/2007 2:22:42 PMPFAIL
Call Michael first, has dog, will bite, needs to secure it.
Electrician is Steve Johnson at ###-#### Phone #: ###-#### called, left message, gfci not wired correctly, shall prove thwn wire is sunlight resistant, span not 10', nm cable not stapled,BCC no violations shall be retained
ELE06-03427 Final4/13/20074/13/20074/13/2007 1:13:18 PMPPASS
The builder said the door was unlocked and building available for insp. The UL floor box sheet is on the front entry vestibule window. Thanks Phone #: ###-#### corr made, ok to cover
ELE07-01194 Electrical Rough-In4/12/20074/13/20074/13/2007 12:26:59 PMPPASS
fire in master only. I have updated 2 AFI ck for bedrooms and added for Bath 20a GFCI ck. Added smokies. home owners are most always home. Front door lock box code 1290. Phone #: ###-#### ric ok
ELE07-00426 Final4/12/20074/13/20074/13/2007 10:40:29 AMAPASS
Phone #: ###-#### called, left message, left survey, nec 350.30(A) lfmc shall be securely fastened in place by an approved means within 12" of each termination point
ELE06-03919 Final4/12/20074/13/20074/13/2007 10:03:18 AMPCANC
May need to call Catherine Trutide @ ###-#### with the City of Boise to access a key for opening the gate if needed for the inspection. Phone #: ###-#### Inspection cancelled from web by: Daniel Gamboa
ELE07-01283 Final4/12/20074/13/20074/13/2007 9:45:51 AMANH
electrician is Nick Felsted at ###-####
resident is Wes Rice at ###-#### Phone #: ###-#### called contr, told nh, need access for inspection
ELE07-01144 Electrical Rough-In4/12/20074/13/20074/13/2007 9:26:27 AMPCANC
brandon ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith Inspection cancelled from web by: Kerri Hamilton
ELE07-00460 Electrical Rough-In4/12/20074/13/20074/13/2007 9:10:09 AMACANC
tony; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see rip
ELE07-00460 Rough-In Permanent Service4/13/20074/13/20074/13/2007 9:08:51 AMAPASS
tony; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok, p/s, u/g, rec(new), ok
ELE06-04635 Final4/12/20074/13/20074/13/2007 8:28:16 AMACANC
Jeff; Phone #: ###-#### Internet Inspection Request from: Stacie Backus elect did not call for insp here, contact notes not affiliated with this job
ELE06-02254 Final4/12/20074/13/20074/13/2007 8:05:38 AMAFAIL
Scheduled by a contractor via Hello! on 4/12/2007 at 2:49:14 PM. Contact: ###-####. met elect, wrote corr notice to owner, nec 110.26, sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. ref. panel 1PF and other panels in elect room 2nd floor behind food court area