MEC20-01446
| Final | 4/13/2020 | 4/13/2020 | 4/13/2020 3:35:08 PM | P | PASS |
|
|
Video/photos ok // Ken Phone #: ###-####- furnace a/c coil co locking caps post ok
|
MEC20-00221
| Final | 4/10/2020 | 4/13/2020 | 4/13/2020 2:50:09 PM | P | FAIL |
|
|
Garage Code: 8118. If this garage code does not work or you need anything pertaining to this residence please contact Alex Macdonald: (###-####) Phone #: ###-#### Inspection requested via web by Terek Worley 1- a/c needs locking caps on service ports 2- waster heater flue needs 3 screws in double wall to single wall flue connection
|
MEC20-00222
| Final | 4/10/2020 | 4/13/2020 | 4/13/2020 2:36:32 PM | P | FAIL |
|
|
Garage Code: 8118. If this garage code does not work or you need anything pertaining to this residence please contact Alex Macdonald: (###-####) Phone #: ###-#### Inspection requested via web by Terek Worley 1- a/c needs locking caps on service ports 2- need to finish sealing range duct thru outside louver missing places on inside
|
MEC20-00302
| Rough-in | 4/13/2020 | 4/13/2020 | 4/13/2020 1:28:07 PM | P | PASS |
|
|
Rough in inspection for Building 11, tower 3, last 6 units... please contact Shawn @ ###-#### Phone #: ###-#### Inspection requested via web by Amanda Casper- R/I units L 109 110 111 112 210 and 212- All units R/I complete for this address-
|
MEC20-01438
| Final | 4/12/2020 | 4/13/2020 | 4/13/2020 11:22:17 AM | A | PASS |
|
|
Please call Chris Mato''s for video inspection. Closer to 11-12pm for inspection. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok- inspection done by virtual video onsite
|
MEC19-04155
| Mec-Aging Inspection | 4/13/2020 | 4/13/2020 | 4/13/2020 9:01:19 AM | | FAIL |
|
|
contractor needs to reschedule inspection no one home last time- permit will expire next aging if no activity- if scheduled before 4-17-20 will require virtual inspection as we can not enter occupied homes at this time- 4-17-20 date may change to later date for covid-19
|
MEC19-04206
| Mec-Aging Inspection | 4/13/2020 | 4/13/2020 | 4/13/2020 8:58:13 AM | | FAIL |
|
|
homeowner needs to call in for R/I inspection on duct work in crawl- only partial was given previsously
|
MEC20-01292
| Rough-in | 4/10/2020 | 4/13/2020 | 4/13/2020 8:50:56 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Tim Petsche- hard lids ok to cover- need engineers approval for the way ducting ran doesnt match approved drawing- need engineer stamped approval onsite before next inspection for the way ducts installed
|
MEC20-00973
| Pressure Test | 4/13/2020 | 4/13/2020 | 4/13/2020 8:18:14 AM | A | PASS |
|
|
20lb gas pass underground from meter to shop- ok to backfill
|