Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04193 Final4/14/20064/14/20064/14/2006 3:30:12 PMPPASS
Garage code is 2468. please call paul@ ###-#### if any problems. Internet Inspection Request from: Paul Young ok corrections made
ELE05-04525 Final4/14/20064/14/20064/14/2006 2:57:20 PMPPASS
ken; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-01293 Rough-In Permanent Service4/14/20064/14/20064/14/2006 2:00:39 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook see correction posted at house Permit #ele04-01292
ELE06-01292 Rough-In Permanent Service4/14/20064/14/20064/14/2006 1:59:41 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook corr. called left message 300.4 nail plates &11/4" everywhere, 250.148 grd all metal boxes , 314.20 all outside boxes shall be flush with combustible material at time of r/i where siding is on house, 250.32(A)(B)(1) needs electrodes at house also shall meet 250.52(A)(1)or 250.104(A)(1) grd or bond, 314.28 conduit cable entries shall bo 12",plastic jbox basement,225.32 needs disconnect at house either outside or inside where first enters, 314.43,110.3, 314.23 no screws in plastic boxes or LBs
ELE06-00251 Final4/14/20064/14/20064/14/2006 12:17:08 PMPPASS
Charlie ###-#### -- ok per Bill Thomas 4-14-06 eus ok
ELE06-00125 Electrical Rough-In4/13/20064/14/20064/14/2006 10:48:43 AMAPART
DENNIS; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
soffits inside
ELE06-01034 Final4/13/20064/14/20064/14/2006 9:59:58 AMAPASS
kevin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-01236 Electrical Rough-In4/13/20064/14/20064/14/2006 9:22:11 AMAFAIL
please inspect the ufer ground for rough in. thanks; Phone #: ###-#### Internet Inspection Request from: steve creswell called left message needs 20 ft of #4 copper and clean dirt out
ELE05-03201 Final4/13/20064/14/20064/14/2006 8:52:56 AMAPASS
CALVIN; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-00808 Rough-In Permanent Service4/13/20064/14/20064/14/2006 8:19:07 AMAPART
Phone #: ###-#### Internet Inspection Request from: Kerri
conference rm ok