Inspections for the day of: Friday, April 14, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01060 Electrical Rough-In4/14/20064/14/20064/14/2006 4:14:11 PMPPASS
Please contact Greg Fisher, remodeling contractor, to assure access to project. Thank you. Greg Fisher; Phone #: ###-#### Internet Inspection Request from: Greg Fisher ric ok kitchen area only
ELE05-02971 Final4/14/20064/14/20064/14/2006 3:58:15 PMPPASS
Caontact Eric Stewart; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong corr made, ok to final
ELE06-01231 Temporary Service4/14/20064/14/20064/14/2006 3:26:10 PMPPASS
Scheduled by a contractor via Hello! on 4/14/2006 at 9:17:53 AM. Contact: ###-####. corr made, t/s u/g n ok
ELE06-01154 Rough-In Permanent Service4/14/20064/14/20064/14/2006 2:44:31 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called contr, left corr notice, 250.86 metal enclosures shall be grounded, 314.20 Boxes in walls constructed of combustible material shall be flush with finished surface, 210.52(A) recepts shall be installed in wall space such that no point is more than 6' from an outlet, 334.80 nm cable shall be derated if 2 or more cables in hole to be draft stopped,BCC there shall be an approved set of plans on job,and all make-up shall be done
ELE05-03276 Permanent Service4/14/20064/14/20064/14/2006 1:36:33 PMPPASS
stu; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections made, available fault current less than main bkr rating, power to house panel, p/s u/g n ok
ELE05-03277 Permanent Service4/14/20064/14/20064/14/2006 1:34:25 PMPPASS
stu; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles told elect to use irreversible connection for gec, available fault current from ipco less than main bkr power to house panel only, p/s u/g n ok
ELE06-01260 Final4/13/20064/14/20064/14/2006 11:52:05 AMACANC
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong wrong type insp, see rip
ELE06-01260 Rough-In Permanent Service4/14/20064/14/20064/14/2006 11:49:58 AMPPASS
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called, left message, box in mbr closet and make-up. ric ok, p/s u/g n ok
ELE06-01288 Final4/14/20064/14/20064/14/2006 10:44:18 AMAPASS
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong see p/s, , ok to final
ELE06-01288 Rough-In Permanent Service4/13/20064/14/20064/14/2006 10:41:52 AMACANC
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong wrong type insp, see p/s and final
ELE06-01288 Permanent Service4/14/20064/14/20064/14/2006 10:36:54 AMAPASS
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong p/s u/g n ok
ELE06-01060 Electrical Rough-In4/13/20064/14/20064/14/2006 10:15:29 AMANH
Chad; Phone #: ###-#### called left message, left notification card
ELE05-02971 Final4/13/20064/14/20064/14/2006 9:34:55 AMAFAIL
Contact Eric Stewart. ; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong called contr, left corr notice, 408.4 both units shall have correct circuit directories and lockouts for dishwasher, 406.4 front recpt shall be secured in box, 210.8 kitchen gfci shall operate correctly and not be tied to rear outside recpt in 4345
ELE06-01207 Electrical Rough-In4/14/20064/14/20064/14/2006 8:53:11 AMAPASS
UG CONDUIT, DEAD END CONDUIT FOR SPA YET TO BE PUT IN PLACE; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack talked to contr, concrete will cover all conduit, ok to backfill u/g
ELE06-01276 Final4/13/20064/14/20064/14/2006 8:21:53 AMAPASS
mobile home hook up Internet Inspection Request from: Andy Rose see p/s, ok to final
ELE06-01276 Permanent Service4/14/20064/14/20064/14/2006 8:21:20 AMAPASS
mobile home hook up Internet Inspection Request from: Andy Rose p/s u/g reconnect exst pedestal, ok