ELE06-01060
| Electrical Rough-In | 4/14/2006 | 4/14/2006 | 4/14/2006 4:14:11 PM | P | PASS |
|
|
Please contact Greg Fisher, remodeling contractor, to assure access to project. Thank you. Greg Fisher; Phone #: ###-#### Internet Inspection Request from: Greg Fisher ric ok kitchen area only
|
ELE05-02971
| Final | 4/14/2006 | 4/14/2006 | 4/14/2006 3:58:15 PM | P | PASS |
|
|
Caontact Eric Stewart; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong corr made, ok to final
|
ELE06-01231
| Temporary Service | 4/14/2006 | 4/14/2006 | 4/14/2006 3:26:10 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 4/14/2006 at 9:17:53 AM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-01154
| Rough-In Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 2:44:31 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called contr, left corr notice, 250.86 metal enclosures shall be grounded, 314.20 Boxes in walls constructed of combustible material shall be flush with finished surface, 210.52(A) recepts shall be installed in wall space such that no point is more than 6' from an outlet, 334.80 nm cable shall be derated if 2 or more cables in hole to be draft stopped,BCC there shall be an approved set of plans on job,and all make-up shall be done
|
ELE05-03276
| Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 1:36:33 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections made, available fault current less than main bkr rating, power to house panel, p/s u/g n ok
|
ELE05-03277
| Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 1:34:25 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles told elect to use irreversible connection for gec, available fault current from ipco less than main bkr power to house panel only, p/s u/g n ok
|
ELE06-01260
| Final | 4/13/2006 | 4/14/2006 | 4/14/2006 11:52:05 AM | A | CANC |
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong wrong type insp, see rip
|
ELE06-01260
| Rough-In Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 11:49:58 AM | P | PASS |
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called, left message, box in mbr closet and make-up. ric ok, p/s u/g n ok
|
ELE06-01288
| Final | 4/14/2006 | 4/14/2006 | 4/14/2006 10:44:18 AM | A | PASS |
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong see p/s, , ok to final
|
ELE06-01288
| Rough-In Permanent Service | 4/13/2006 | 4/14/2006 | 4/14/2006 10:41:52 AM | A | CANC |
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong wrong type insp, see p/s and final
|
ELE06-01288
| Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 10:36:54 AM | A | PASS |
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong p/s u/g n ok
|
ELE06-01060
| Electrical Rough-In | 4/13/2006 | 4/14/2006 | 4/14/2006 10:15:29 AM | A | NH |
|
|
Chad; Phone #: ###-#### called left message, left notification card
|
ELE05-02971
| Final | 4/13/2006 | 4/14/2006 | 4/14/2006 9:34:55 AM | A | FAIL |
|
|
Contact Eric Stewart. ; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong called contr, left corr notice, 408.4 both units shall have correct circuit directories and lockouts for dishwasher, 406.4 front recpt shall be secured in box, 210.8 kitchen gfci shall operate correctly and not be tied to rear outside recpt in 4345
|
ELE06-01207
| Electrical Rough-In | 4/14/2006 | 4/14/2006 | 4/14/2006 8:53:11 AM | A | PASS |
|
|
UG CONDUIT, DEAD END CONDUIT FOR SPA YET TO BE PUT IN PLACE; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack talked to contr, concrete will cover all conduit, ok to backfill u/g
|
ELE06-01276
| Final | 4/13/2006 | 4/14/2006 | 4/14/2006 8:21:53 AM | A | PASS |
|
|
mobile home hook up Internet Inspection Request from: Andy Rose see p/s, ok to final
|
ELE06-01276
| Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 8:21:20 AM | A | PASS |
|
|
mobile home hook up Internet Inspection Request from: Andy Rose p/s u/g reconnect exst pedestal, ok
|