Inspections for the day of: Thursday, April 14, 2016.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-00907 BLD-Framing/Rough-in4/14/20164/14/20164/14/2016 3:46:13 PMPPASS
would like call ahead; Kent Phone #: ###-####. Ok to insulate.
BLD15-03823 BLD-Final4/14/20164/14/20164/14/2016 3:07:56 PMPPART
Call 30 minutes before // Hamish Phone #: ###-####. Ok for temp occ. Need RFI from enfineer on alternate parapet bracing and transitions into roll in showers.
BLD15-01921 BLD-Framing/Rough-in4/14/20164/14/20164/14/2016 2:44:23 PMPPASS
Kent-early if possible Phone #: ###-####. All framing issues have been resolved. Ok to insulate. Advise Kent to reschedule mech. rough in inspection and noted to him the correction notice from mech. to resubmit plans.
BLD16-00804 BLD-Framing/Rough-in4/14/20164/14/20164/14/2016 2:42:45 PMPPASS
would like call ahead; Dennis Phone #: ###-####
MIS16-00118 BLD-Final4/14/20164/14/20164/14/2016 2:30:33 PMPDONE
as per Tim Woodard- request to verify c of o of Boise Granit on east end of building. A correction notice was issued to provide T.I. plans and get all required inspedtions to obtain a certificate of occupancy.
BLD16-00722 BLD-Final4/14/20164/14/20164/14/2016 2:28:46 PMPPASS
JERIMY Phone #: ###-####
BLD16-00299 BLD-Wall Bracing4/14/20164/14/20164/14/2016 2:28:43 PMPPASS
Bendi Phone #: ###-####
BLD16-00722 DOC - Permit Finaled4/14/20164/14/20164/14/2016 2:28:19 PMPPASS
GCB15-00090 GCB-Fndatn/slab ins/fld vent4/13/20164/14/20164/14/2016 11:11:27 AMAPASS
Chris ###-#### - rebar insp. east exterior stemwall ok.
BLD16-00783 BLD-Framing/Rough-in4/13/20164/14/20164/14/2016 10:20:29 AMAPASS
Preston Phone #: ###-####
BLD15-04503 BLD-Framing/Rough-in4/13/20164/14/20164/14/2016 9:59:51 AMAPART
Cecle Phone #: ###-####. Interior steel stud framed walls and hardlid ok. Noted opening protection issues behind transfer shower at rated wall. NO rock installed behind shower, also membrane protection for shower valve?
BLD16-00896 BLD-Framing/Rough-in4/13/20164/14/20164/14/2016 9:13:17 AMAPASS
SPENCE Phone #: ###-####. Interior wood stud walls ok.
BLD15-01551 BLD-Final4/13/20164/14/20164/14/2016 8:58:19 AMAPASS
Jake Phone #: ###-####. Ok for perm occ.