Inspections for the day of: Friday, April 14, 2017.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-01367 Final4/14/20174/14/20174/14/2017 4:34:48 PMPPASS
We will call insp when flue is pressured and we are about done Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
MEC17-01287 Final4/10/20174/14/20174/14/2017 4:23:16 PMPPASS
LATE PM if possible. please call installer Jarod at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Ben Welgan
MEC17-01367 Pressure Test4/14/20174/14/20174/14/2017 3:43:14 PMPPASS
Flue Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- 5lb flue pass
MEC17-00225 Pressure Test4/11/20174/14/20174/14/2017 3:20:46 PMPCANC
Phone #: ###-#### Inspection requested via web by Ed Ables- talked to Ed he will reschedule this for Ben-
MEC17-01371 Final4/14/20174/14/20174/14/2017 2:52:58 PMPPASS
Please contact the installer Jesse at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Ben Welgan
MEC17-00648 Final4/12/20174/14/20174/14/2017 2:28:05 PMPPASS
This failed due to no economizer the first time, I have been told this is resolved. AM/PM doesn''t matter someone is there from 8-5. Phone #: ###-#### Inspection requested via web by Nicole Kimball
MEC17-00688 Final4/14/20174/14/20174/14/2017 2:05:26 PMPFAIL
Would like PM and Call when on way Phone #: ###-#### Inspection requested via web by Xanti Berria- b vent in garage needs 1" clearance to combustibles and trim ring installed and remove fire caulk at ceiling level- need 3 screws per joint in b vent flue pipe at water heater- outside air to R/A plenum needs insulated- seal joints on R/A plenum off furnace???- left correction notice on furnace in garage-
MEC17-01248 Rough-in4/14/20174/14/20174/14/2017 1:27:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Ed Ables
MEC17-01248 Pressure Test4/14/20174/14/20174/14/2017 1:27:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Ed Ables- 20lb gas pass
MEC17-01278 Rough-in4/14/20174/14/20174/14/2017 12:03:57 PMPNR
Inspection requested via web by Konrad Swartz- crawl needs finished- exhaust fan needs hooked in basement
MEC17-01278 Pressure Test4/14/20174/14/20174/14/2017 12:03:10 PMPPASS
Inspection requested via web by Konrad Swartz- 20lb gas pass- flue test not needed
MEC17-01199 Rough-in4/13/20174/14/20174/14/2017 11:27:38 AMAPASS
Braxton ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC17-01352 Rough-in4/13/20174/14/20174/14/2017 11:20:02 AMAPASS
BRAXTON ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC17-00528 Final4/13/20174/14/20174/14/2017 10:57:44 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC16-04607 Final4/12/20174/14/20174/14/2017 10:46:11 AMAFAIL
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- need fresh air ducts insulated in garage- need louvers on 6" fresh air intake outside-
MEC17-01248 Rough-in4/13/20174/14/20174/14/2017 10:10:55 AMAFAIL
Phone #: ###-#### Inspection requested via web by Ed Ables- need installation instructions onsite-
MEC17-01248 Pressure Test4/13/20174/14/20174/14/2017 10:10:19 AMAFAIL
gas test for range Phone #: ###-#### Inspection requested via web by Ed Ables- guage wont zero out
PLM17-01177 Water Heater Final4/13/20174/14/20174/14/2017 9:56:50 AMAFAIL
please contact home owner with approximate time (Don Thrash ###-####) Phone #: ###-#### Inspection requested via web by Roy Towers- T&P needs turned down- tank has rattle in it- contractor aware of issue per homeowner
MEC17-01250 Rough-in4/10/20174/14/20174/14/2017 9:34:51 AMAPASS
GARA ###-####
HOMEOWNER REQUESTS: early as possible, please Phone #: ###-#### Inspection requested via web by Jason Robinson