BLD04-01267
| BLD-Wall cover | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 4/14/2005 at 4:07:58 PM. Framing at pool cover OK but need to check (2) 4-6' shear panels Ea. side of openig @ East wall (6" oc nailing) 4/15/2005 9:57:48 AM 4/15/2005 9:58:20 AM
|
BLD04-02863
| BLD-Final | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PASS |
|
|
###-#### OK for Perm Occ. :) 4/15/2005 4:30:55 PM
|
BLD04-01073
| BLD-Final | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | FAIL |
|
|
scott; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Told Scott that I need Mech approval for revised conditioned crawlspace B 4 I final. 4/15/2005 11:11:28 AM
|
BLD05-00860
| BLD-Framing/Rough-in | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/14/2005 at 1:38:32 PM. Contact: ###-####.
|
BLD05-00860
| BLD-Energy code compliance | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/14/2005 at 1:39:08 PM. Contact: ###-####.
|
BLD04-01051
| BLD-Conference | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PART |
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Ok to rock lid... exept Kitch and portion below 2nd story. 4/15/2005 12:02:22 PM
|
BLD04-01882
| BLD-Conference | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | CANC |
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-00268
| BLD-Final | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | A | PASS |
|
|
darren ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie C/C issued. 4/15/2005 10:30:58 AM
|
BLD05-00605
| BLD-Footing | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
###-####
|
BLD03-03031
| BLD-Framing/Rough-in | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
ron Note: shear nail inspection on frame; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Shear nailing and roof nailing OK. 4/15/2005 3:04:36 PM
|
BLD05-00176
| BLD-Framing/Rough-in | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | FAIL |
|
|
val; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Steve Munroe called and said that Marlene wanted a stop work on this house because of promblem with subdivision req. (not disclosed) 4/15/2005 2:25:57 PM
|
BLD04-01721
| BLD-Framing/Rough-in | 4/14/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 4/14/2005 at 5:13:11 PM. Contact: ###-####. OK to Insulate....Need to inspect for firestopping at blocking (fireblock) 4/15/2005 12:33:53 PM
|
BLD05-00706
| BLD-Foundation | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 4/15/2005 at 7:53:50 AM. Contact: ###-####. Footing for Bsmnt and crawl appears OK. 4/15/2005 3:12:06 PM
|
BLD05-00499
| BLD-Framing/Rough-in | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
shear inspection please///john; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Conf on stairway.....New code does not req. continuous handrail on inside for winders. 4/15/2005 2:30:50 PM
|
BLD04-02205
| BLD-Framing/Rough-in | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PASS |
|
|
richard; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00765
| BLD-Footing | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00764
| BLD-Footing | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00662
| BLD-Footing | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00607
| BLD-Foundation | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00666
| BLD-Foundation | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00661
| BLD-Foundation | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PART |
|
|
manuel; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD05-00179
| BLD-Final | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | PASS |
|
|
###-#### larry C/C issued. 4/15/2005 3:43:40 PM
|
MIS05-00032
| BLD-Final | 4/15/2005 | 4/15/2005 | 4/15/2005 12:00:00 AM | P | NR |
|
|
late pm??-- randy --for the steps; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|