ELE10-01289
| ELE-Aging Inspection | 4/15/2015 | 4/15/2015 | 4/17/2015 7:15:09 AM | | DONE |
|
|
too busy
|
ELE14-03205
| Final | 4/15/2015 | 4/15/2015 | 4/15/2015 2:34:23 PM | P | PASS |
|
|
General Contractor needs his card signed. Steve Mitchell ###-#### Phone #: ###-#### Inspection requested via web by Bryan Atkins final ok
|
GCE14-00207
| GCE-Rough-In | 4/15/2015 | 4/15/2015 | 4/15/2015 1:11:25 PM | P | PASS |
|
|
Kevin Burke ###-#### inspection request for light pole bases u.ground raceways to poles ok and pole bases ok to pour
|
ELE15-00055
| Final | 4/14/2015 | 4/15/2015 | 4/15/2015 1:01:40 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 110.24(A)- Available fault current shall be permenently labeled on main disconnect with date. 210.8(B)(2)-all 15 and 20amp 120volt receptacles shall be GFCI protected in non dwelling kitchens. Panel covers need to be in place with directories.
|
ELE15-01030
| Permanent Service | 4/15/2015 | 4/15/2015 | 4/15/2015 11:36:46 AM | A | PASS |
|
|
I will Lable panel when power is back on Phone #: ###-#### Inspection requested via web by Jason Wicks p/s o/h rec ok NOTE TO CONTRACTOR :Meter should be at 5' 6" to center whenever possible + or - 6"
|
ELE15-01031
| Electrical Rough-In | 4/15/2015 | 4/15/2015 | 4/15/2015 10:46:09 AM | A | FAIL |
|
|
Partial rough in. Everything except the back wall where service will be set. Owner talking with idaho power to see if service can be brought in from underground. Phone #: ###-#### Inspection requested via web by Jason Wicks 300.4=11/4" required from edge of stud to bored hole or use nailplates. 210.52(E)(1)-for a family dwelling at least one receptacle outlet readilly accessable fromgrade shall be installed at front and back of dwelling. 210 70(A)(2)(b)-in dwelling units at least one wall switch controlled lighting outlet shall be installed to provide illumination on the exterior side of outdoor entrances or exits @ grade level.
|
ELE14-03336
| Electrical Rough-In | 4/14/2015 | 4/15/2015 | 4/15/2015 9:50:19 AM | A | PASS |
|
|
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden r/i ok clubhouse stairwell wall, wing 1 level 2 corridor soffits above doors
|
ELE14-03246
| Electrical Rough-In | 4/14/2015 | 4/15/2015 | 4/15/2015 9:18:24 AM | A | PASS |
|
|
Dave. Tower 5th Floor Soffit Cover. Phone #: ###-#### Inspection requested via web by Sean DeLacy tower1 and 2 level 5 corridors ok to cover. Also discuss pool bonding and countertop kitchen receptacle spacing
|
ELE15-00432
| Final | 4/14/2015 | 4/15/2015 | 4/15/2015 7:44:15 AM | A | CANC |
|
|
Geoff Hannaford is contact at ###-####. thank you. Phone #: ###-#### >> Inspection requested via web by Debby Pierce Inspection cancelled from web by: Debby Pierce
|
ELE15-02082
| Electrical Rough-In | 4/14/2015 | 4/15/2015 | 4/15/2015 12:00:00 AM | A | PASS |
|
|
Ceiling Inspection, SkyWest Contact Shawn Evins Phone #: ###-#### Inspection requested via web by Cathy Duchek r/i hard lid ceilings west end ok
|
ELE15-02132
| Electrical Rough-In | 4/15/2015 | 4/15/2015 | 4/15/2015 12:00:00 AM | A | PASS |
|
|
Shaft walls on 2nd floor for cover. Look over roof progress over east end of building. Phone #: ###-#### Inspection requested via web by Rafael Castillo partial r/i ok 2 hr vent. shafts in rms. 202 thru 204, 206,211 and 212 NOTE: walk with Rafael to see if roof is complete on east wing and it is not done. No electrical wire in this area or any areas not dried in.
|
ELE15-01015
| Electrical Rough-In | 4/14/2015 | 4/15/2015 | 4/14/2015 3:34:07 PM | A | CANC |
|
|
We are requesting wall rough-in inspections for the Bldg. 2L IDF and Focus rooms for tomorrow 4/15/15 during the AM. Our onsite contact is Rich @ ###-####. Thank you! Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
|
ELE15-01015
| Electrical Rough-In | 4/14/2015 | 4/15/2015 | 4/14/2015 9:44:02 AM | A | CANC |
|
|
We are requesting a wall rough-in inspection for tomorrow 4/15/15 in the AM. Our onsite contact is Rich @ ###-####. This will be in Bldg. 2L IDF area. Thank you! Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
|