ELE13-00755
| ELE-Aging Inspection | 4/16/2018 | 4/16/2018 | 4/17/2018 7:13:20 AM | | DONE |
|
|
Please schedule for a final inspection.
|
ELE16-03739
| ELE-Request for Extension | 4/16/2018 | 4/16/2018 | 4/16/2018 2:40:08 PM | P | CANC |
|
|
Keith // homeowner doing own work plans on continuing work this summer Phone #: ###-#### Re-scheduled for 4/17/18. Called and left message with homeowner. No return call.
|
ELE18-01438
| Temporary Service | 4/16/2018 | 4/16/2018 | 4/16/2018 2:37:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Berthelot t/s u/g n ok
|
ELE18-01436
| Temporary Service | 4/16/2018 | 4/16/2018 | 4/16/2018 2:37:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Berthelot t/s u/g n ok
|
ELE18-01423
| Electrical Rough-In | 4/13/2018 | 4/16/2018 | 4/16/2018 1:54:45 PM | P | PASS |
|
|
NEED OK TO COVER Phone #: ###-#### Inspection requested via web by Same Electric Ok cover.
|
ELE18-00997
| Final | 4/16/2018 | 4/16/2018 | 4/16/2018 12:56:59 PM | P | FAIL |
|
|
Use contractor box on porch.. # is 5544 The Irene street porch Thanks Inspection requested via web by Eddy Udry 1. GFI not tamper resistant in W bed. 2. ARC fault recept installed in other bed, needs to be GFI. Also recept has no power. 3. Faceplates need to be of adequate strength to withstand foot traffic. Metal faceplates needed.
|
ELE18-00513
| Final | 4/16/2018 | 4/16/2018 | 4/16/2018 12:10:24 PM | P | PASS |
|
|
Contact Tom MacIntyre at ###-#### or Steve McCloy at ###-#### with any questions or concerns. Inspection requested via web by Steve McCloy Ok final. All corrections made. Floor heat in utility and mstr bath is UL listed. Paperwork was onsite. Both thermostats operate properly.
|
ELE18-01361
| Rough-In Permanent Service | 4/13/2018 | 4/16/2018 | 4/16/2018 9:52:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall p/s u/g n ok
|
ELE18-01360
| Rough-In Permanent Service | 4/13/2018 | 4/16/2018 | 4/16/2018 9:51:57 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall p/s u/g n ok
|
ELE18-01351
| Permanent Service | 4/13/2018 | 4/16/2018 | 4/16/2018 9:17:58 AM | A | PASS |
|
|
key for access located in temporary service box Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON p/s o/h n ok. 2 grd rods installed.
|
ELE18-01423
| Electrical Rough-In | 4/13/2018 | 4/16/2018 | 4/13/2018 4:05:59 PM | A | CANC |
|
|
NEED OK TO COVER Phone #: ###-#### >> Inspection requested via web by Same Electric Inspection cancelled from web by: Same Electric
|