ELE19-00478
| Final | 4/15/2019 | 4/16/2019 | 4/16/2019 3:01:54 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by ERIC CENTERS Mike found non listed heater controls that did not work. Will recall when ready
|
ELE19-01043
| Final | 4/16/2019 | 4/16/2019 | 4/16/2019 2:35:41 PM | P | FAIL |
|
|
Code 2010 on lock box on side door Phone #: ###-#### Inspection requested via web by Jason Wicks 314.21- Drywall shall be repaired around boxes and panel so that no gap is greater than 1/8" around edges. 314.25- All boxes shall have covers. Switch in driveway storage, micro not trimmed, disposal receptacle not trimmed. 408.4- Outdoor circuit directory shall be complete and accurate. 422.31- Water heater shall have a disconnecting means. 110.25 lockouts acceptacle.
|
ELE18-02369
| Electrical Rough-In | 4/16/2019 | 4/16/2019 | 4/16/2019 1:42:55 PM | P | NH |
|
|
1st through 4th Floor elevator lobby wall rough-in. Call Joey Campbell prior to arrival. Phone #: ###-#### Inspection requested via web by Scott Campbell Called twice unable to leave message, mail obx full. Recall when available.
|
ELE18-01608
| Conference | 4/16/2019 | 4/16/2019 | 4/16/2019 1:29:31 PM | P | DONE |
|
|
Questions regarding bonding in outdoor otter exhibit Phone #: ###-#### Inspection requested via web by Mike McCarrel Questiion is for bonding of rebar located on interior of artificial rocks in contact with water. No electrical equipment in or on otter pond, no metal likely to become energized as per 682.32. Equipotential plane will be needed for equipment disconnecting means as per 682.33.
|
ELE19-01337
| Electrical Rough-In | 4/15/2019 | 4/16/2019 | 4/16/2019 11:33:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot Called contractor about wires coiled in wall to right of vanity and at rear wall by tub, no answer will check at final. Master bath addition rough in ok cover
|
ELE19-01307
| Rough-In Permanent Service | 4/15/2019 | 4/16/2019 | 4/16/2019 10:39:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE19-01338
| Rough-In Permanent Service | 4/15/2019 | 4/16/2019 | 4/16/2019 10:01:45 AM | A | PASS |
|
|
service for cable tv power supply alpha cabinet . located at ne corner of 2987 Christine.contact # 2088694390 Andy. Phone #: ###-#### Inspection requested via web by andrew dopieralski Service noted rough in ok p/s u/g n ok
|
ELE19-01265
| Electrical Rough-In | 4/15/2019 | 4/16/2019 | 4/16/2019 9:42:27 AM | A | PASS |
|
|
Joe Phone #: ###-#### Kitchen wall furred out and laundry wall in mechanical room rough in ok cover
|