Inspections for the day of: Tuesday, April 16, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01410 Rough-in4/16/20194/16/20194/16/2019 3:43:00 PMPFAIL
New home construction rough in and pressure test. Permit and Man J onsite. Phone #: ###-#### Inspection requested via web by Lynn Johnston
- need manufactures approved nail plates for gas flex
- condensate line upstairs needs nail plates installed
MEC19-01410 Pressure Test4/16/20194/16/20194/16/2019 3:41:42 PMPPASS
New home construction rough in and pressure test. Permit and Man J onsite. Phone #: ###-#### Inspection requested via web by Lynn Johnston
- 20lb gas pressure test ok
tagged meter location
MEC19-01436 Rough-in4/16/20194/16/20194/16/2019 3:40:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Jose Lagunas
- R/I ok
MEC18-03675 Final4/16/20194/16/20194/16/2019 2:29:59 PMPPASS
Please call the number provided when on the way out. Phone #: ###-#### Inspection requested via web by Steve Bunch
- final ok
MEC19-01486 Final4/16/20194/16/20194/16/2019 2:04:52 PMPPASS
Doug ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- mini split final ok
MEC19-01418 Final4/15/20194/16/20194/16/2019 1:35:27 PMPPASS
Please call Max in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- furnace only co ok
MEC19-01528 Pressure Test4/16/20194/16/20194/16/2019 1:17:06 PMPNR
Gas piping pressure test. Contact Steve with questions. Or Cory, if Steve is unavailable ###-####. Phone #: ###-#### Inspection requested via web by Steve Torgerson
MEC19-00581 Rough-in4/16/20194/16/20194/16/2019 11:26:15 AMAFAIL
-B vent for both pool heaters has screws penetrating inner pipe and needs to be changed out
- both vents need an insulation sheild intalled to maintain 1" clearances
MEC19-00412 Final4/15/20194/16/20194/16/2019 11:25:22 AMAFAIL
Jarrod: ###-####
Access: 9378 Phone #: ###-#### Inspection requested via web by Frank Marturello
- duct blast needs to be performed
MEC19-01292 Rough-in4/15/20194/16/20194/16/2019 10:10:49 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino
- transfer air upstairs needs finished
- check equipment to man J at final
MEC19-01292 Pressure Test4/15/20194/16/20194/16/2019 10:08:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
- 20lb gas pressure test ok
- 5lb flue pressure test ok
- tagged meter location
MEC19-01229 Rough-in4/15/20194/16/20194/16/2019 10:07:48 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino
- need duct layout in man J
- check equipment to man J at final
MEC19-01229 Pressure Test4/15/20194/16/20194/16/2019 10:06:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
- 20lb gas pressure test ok
- 5lb flue pressure test ok
- tagged meter location
MEC19-01507 Rough-in4/15/20194/16/20194/16/2019 9:23:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Angie Thome
- need stamped man J. onsite
- gas line for bbq needs protective wrap installed at penetration
MEC19-01507 Pressure Test4/15/20194/16/20194/16/2019 9:22:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Angie Thome
- 20lb gas pressure test ok
- tagged meter location
MEC19-00162 Rough-in4/15/20194/16/20194/16/2019 8:41:26 AMAPASS
Seal inspection for corridor. Steve will be the contact. Please call 1/2 hour prior so Steve can meet you. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams
- Duct seal ok
- ok for insulation
MEC19-01204 Final4/15/20194/16/20194/15/2019 9:27:03 AMACANC
Please call Corey at ###-#### when in route Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority
MEC19-01204 Pressure Test4/15/20194/16/20194/15/2019 9:27:01 AMACANC
Please call Corey at ###-#### when in route Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority
MEC19-00411 Final4/12/20194/16/20194/12/2019 3:54:21 PMACANC
Access: 9378
Jarod: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello Inspection cancelled from web by: Frank Marturello