Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-01492 Final4/15/20204/16/20204/16/2020 3:39:52 PMPPASS
Please contact Steven, the installer, ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok
MEC20-01494 Final4/15/20204/16/20204/16/2020 3:01:13 PMPPASS
Please contact Craig, the installer, ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- fuirnace a/c coil co locking caps ok
PLM20-01619 Water Heater Final4/15/20204/16/20204/16/2020 2:56:57 PMPPASS
Please contact Craig, the installer, ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
MEC20-00511 Final4/16/20204/16/20204/16/2020 2:13:25 PMPPART
if questions call Nolan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann- phase 1 gas piping final only ok- piping under 10'
MEC20-00354 Conference4/15/20204/16/20204/16/2020 1:22:06 PMPDONE
please call Dru prior to arrival to set time and access location. This is a conference. ###-#### Phone #: ###-#### Inspection requested via web by Nicholas Paige- Met with Chad and Dru onsite- see Chad S notes
MEC20-00501 Final4/15/20204/16/20204/16/2020 10:55:03 AMAPART
Temp occupancy - call cy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- temp occupancy phase 1 only ok
MEC20-00762 Final4/13/20204/16/20204/16/2020 10:14:48 AMAFAIL
2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need approved man j onsite- need 3 screws in b vent to china cap on water heater- duct blast sticker on panel needs filled out completely missing results- smell gas in furnace closet turned off gas valve
MEC20-01406 Rough-in4/15/20204/16/20204/16/2020 9:58:13 AMAPASS
vidoe/photo ok // Ben Phone #: ###-####- supply in crawl via text pics ok- wxhaust fan ok homeowner is going to change out to insulated flex will send pic
MEC19-04266 Mec-Aging Inspection4/16/20204/16/20204/16/2020 8:26:22 AM FAIL
contractor needs to install co detector per last inspection- send pic if completed- permit will expire next aging if no activity
MEC19-04159 Mec-Aging Inspection4/16/20204/16/20204/16/2020 8:25:18 AM FAIL
contractor needs to schedule final inspection- permit will expire next aging if no activity
MEC20-01485 Rough-in4/15/20204/16/20204/15/2020 9:25:36 AMACANC
Cover inspection - call david Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen Inspection cancelled from web by: Brandon Sorensen