BLD01-00536
| BLD-Framing/Rough-in | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 04/16/2001 at 08:40:11. Contact: ###-####. c/n on site 4/17/2001 11:08:37 AM
|
BLD00-02582
| BLD-Final | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 04/16/2001 at 11:03:37. Contact: ###-####.
|
BLD00-03722
| BLD-Framing/Rough-in | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
fr bob-- ###-####
|
MEC01-01015
| Rough-in | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 04/16/2001 at 15:00:45. Contact: ###-####.
|
MEC01-01082
| Rough-in | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 04/16/2001 at 15:01:32. Contact: ###-####.
|
MEC01-00591
| Final | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 04/16/2001 at 15:02:18. Contact: ###-####.elec wiring to furnace and fans noy complete gas piping in crawel space not supported hvac boots not insulated flax duct not supported every 4ft 4/17/2001 10:28:39 AM
|
MEC01-01113
| Rough-in | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
###-####
|
MEC01-01113
| Pressure Test | 4/16/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
|
MEC01-00847
| Final | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 04/17/2001 at 07:24:29. Contact: ###-####. fans not insalled no elec to house 4/17/2001 9:56:15 AM
|
BLD01-00438
| BLD-Framing/Rough-in | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | A | PASS |
|
|
Added by Inspector: 425 On 4/17/2001 11:21:48 AM
|
BLD01-00640
| BLD-Energy code compliance | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | FAIL |
|
|
###-#### 4/17/2001 1:42:16 PM c/n items not completed 4/17/2001 1:42:41 PM
|
BLD01-00664
| BLD-Framing/Rough-in | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | PASS |
|
|
SHEAR NAIL\\###-####
|
BLD01-00314
| BLD-Final | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | FAIL |
|
|
JP ###-#### c/n on site 4/17/2001 2:04:17 PM
|
BLD01-00399
| BLD-Final | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | FAIL |
|
|
###-#### c/n on site 4/17/2001 2:34:27 PM
|
BLD01-00453
| BLD-Final | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | FAIL |
|
|
###-#### house not ready no flooring or finish work done along with a number of other item to many to start 4/17/2001 1:45:02 PM
|
BLD00-01225
| BLD-Framing/Rough-in | 4/17/2001 | 4/17/2001 | 4/17/2001 12:00:00 AM | P | NR |
|
|
###-#### CALL FIRST
|