Inspections for the day of: Thursday, April 17, 2003.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-01511 BLD-Aging Inspection4/17/20034/17/20034/17/2003 12:00:00 AM PART
wip 4/17/2003 8:08:04 AM
BLD02-01078 BLD-Aging Inspection4/17/20034/17/20034/17/2003 12:00:00 AM PASS
BLD03-00381 BLD-Final4/16/20034/17/20034/17/2003 12:00:00 AMAPASS
wayne ; Phone #: ###-#### Internet Inspection Request from: Annette Moore as per aproved plans l/c isued. 4/16/2003 3:58:04 PM
BLD02-01843 BLD-Framing/Rough-in4/16/20034/17/20034/17/2003 12:00:00 AMAPART
eric; Phone #: ###-#### Internet Inspection Request from: Annette Moore c/n fire blk plumbing chase / finsh mech framing 2nd floor and fire blk/ seal wire at top plate in garage/ instal 1 hr soffit on garage eave. ok to insulate. 4/17/2003 9:40:39 AM
MIS03-00069 BLD-Final4/16/20034/17/20034/17/2003 12:00:00 AMAPASS
CALL 1ST FOR ACCESS DANA BRAZELL ###-####
BLD03-00290 BLD-Framing/Rough-in4/17/20034/17/20034/17/2003 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 4/17/2003 at 6:44:22 AM. Contact: ###-####.c/n joist top chord cut mid span under tub / fire blk mech chase kitcthen/fans not conected to ducts/ ele boxes not sealed at attic./ floor pony wall sill plat not anchored to footing in crawl space/ joist at furnce un supported./ new u values for windows pending report approval from plan review. 4/17/2003 10:04:37 AM
BLD03-00040 BLD-Framing/Rough-in4/14/20034/17/20034/17/2003 12:00:00 AMPPART
###-#### exterior ok to cover. 4/18/2003 1:30:19 PM
BLD02-02922 BLD-Final4/16/20034/17/20034/17/2003 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 4/16/2003 at 9:50:52 PM. Contact: ###-####.
BLD02-03062 BLD-Framing/Rough-in4/16/20034/17/20034/17/2003 12:00:00 AMPPART
MARK ; Phone #: ###-#### Internet Inspection Request from: Annette Moore shaft clearance ok to duct need fire stoping at lower penatations. 4/17/2003 3:22:04 PM
BLD00-03428 BLD-Conference4/17/20034/17/20034/17/2003 12:00:00 AMPPASS
CALVIN ###-#### verified tempered on glazing pannels at rotunda at half way point of instulation./ third floor fire stopping in progess. 4/17/2003 3:20:56 PM
BLD02-02112 BLD-Final4/17/20034/17/20034/17/2003 12:00:00 AMPPASS
420 ok 4/18/2003 8:21:21 AM