Inspections for the day of: Tuesday, April 17, 2007.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-00221 Final4/17/20074/17/20074/17/2007 3:11:50 PMPNH
Shawn ; Phone #: ###-#### Internet Inspection Request from: Darla Downs no access
PLM07-01187 Plumbing Rough-in4/17/20074/17/20074/17/2007 3:11:14 PMPFAIL
Dan; Phone #: ###-#### Internet Inspection Request from: Darla Downs reduction of existing 4" horizontal waste to 3" is prohibited. kitchen sink vent must be 6" above tub rin before connecting. nail plate kitchen sink vent and tub waste at wall top plate.
PLM07-00800 Final4/16/20074/17/20074/17/2007 2:42:34 PMPPASS
Lori ; Phone #: ###-####5 Internet Inspection Request from: Darla Downs final ok
PLM06-03834 Final4/16/20074/17/20074/17/2007 9:27:32 AMANR
Rocky; Phone #: ###-#### Internet Inspection Request from: Stacie Backus still needs sprinkler permit
PLM07-01194 Plumbing Rough-in4/16/20074/17/20074/17/2007 9:18:05 AMAPASS
Eddie; Phone #: ###-#### Internet Inspection Request from: Stacie Backus 955 is whats above the door ri ok
PLM07-01199 Sprinkler (Final)4/16/20074/17/20074/17/2007 8:53:03 AMANR
Spud ; Phone #: ###-#### Internet Inspection Request from: Stacie Backus dcva not tested