Inspections for the day of: Wednesday, April 17, 2013.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01260 ELE-Aging Inspection4/17/20134/17/20134/23/2013 2:16:56 PM DONE
Job appears close to finished. Contractor still wating on owner
ELE13-00809 Electrical Rough-In4/16/20134/17/20134/17/2013 3:43:40 PMPPASS
joe Phone #: ###-#### Underground from garage to house rough in ok cover
ELE13-00809 Permanent Service4/17/20134/17/20134/17/2013 3:42:19 PMPPASS
joe Phone #: ###-#### p/s o/h n ok
ELE12-02909 Final4/17/20134/17/20134/17/2013 3:14:00 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Jim Williams
410.8 Master closet light shall have tatally enclosed bulbs.
210.8 2 car garage door recepticals shall be GFCI protected.
250. utility ground bar shall be provided.
MIS13-00093 ELE-Conference4/17/20134/17/20134/17/2013 2:14:45 PMPFAIL
Abserved electrical for ac units being installed on 4-15-13. posted correction notice and spoke with electrical contractor and informed of double fees on ele and hvac.
ELE13-00858 Final4/17/20134/17/20134/17/2013 2:11:03 PMPFAIL
you can contact homeowner Teressa for access if needed @ ###-####. Eclectrical contractor can be reached @ ###-#### THANK YOU Phone #: ###-#### >> Inspection requested via web by Robert Nelson
680.42(B) All metal not associated with hot rub that is located with in 5' horizontal and 12' vertical of the inside wall shall be bonded
ELE13-00923 Temporary Service4/17/20134/17/20134/17/2013 1:36:52 PMPPASS
toli Phone #: ###-#### Owner to get ground rod to finished grade t/s u/g n ok
ELE13-00932 Electrical Rough-In4/17/20134/17/20134/17/2013 12:25:43 PMPPASS
National Industrial Supply Phone #: ###-#### >> Inspection requested via web by Matthew White UL listed materials confirmed. Rough in ok cover
ELE12-02676 Final4/17/20134/17/20134/17/2013 11:55:59 AMPPASS
Service change required due to damage permit # ELE13-00926. Final ok
ELE11-02804 Final4/17/20134/17/20134/17/2013 11:01:25 AMPPASS
>> Inspection requested via web by Don Conley Finaled complete job with permit # ele12-02165. Final ok
ELE12-01776 Final4/17/20134/17/20134/17/2013 10:59:13 AMPPASS
>> Inspection requested via web by Don Conley Finaled complete job with permit # ele12-02165. final ok
ELE11-02806 Electrical Rough-In4/16/20134/17/20134/17/2013 10:51:28 AMAPASS
3rd floor ceiling . elevator lobby and north hallway...see plans for highlighted areas call mike 1/2 prior ###-#### Phone #: ###-#### >> Inspection requested via web by Shawna Gates please the areas open to check boxes marked on print. rough in ok cover
ELE13-00055 Final4/16/20134/17/20134/17/2013 10:10:23 AMAPART
Phone #: ###-#### >> Inspection requested via web by Phil Baker
1 recept. cover missing and dishwasher wire exposed
ELE13-00926 Permanent Service4/16/20134/17/20134/17/2013 9:41:48 AMAPASS
INSPECT PERMANENT SERVICE Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY p/s u/g rec ok
ELE13-00926 Final4/17/20134/17/20134/17/2013 9:41:28 AMPPASS
INSPECT PERMANENT SERVICE Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY Service change final ok
ELE13-00687 Final4/17/20134/17/20134/17/2013 9:21:06 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Don Conley Service change final ok
GCE13-00040 GCE-Rough-In4/16/20134/17/20134/17/2013 8:55:20 AMAPASS
Neal ###-#### rough in for master bath requested Master bath wall rough in ok cover
GCE12-00080 GCE-Final4/16/20134/17/20134/17/2013 8:36:31 AMAPASS
(Mandatory Inspection) Greg ###-#### Final ok
GCE13-00061 GCE-Rough-In Permanent Service4/16/20134/17/20134/17/2013 8:13:41 AMAPASS
(Mandatory Inspection) Terry ###-####
Rough in ok cover p/s u/g n ok