Inspections for the day of: Wednesday, April 17, 2013.
Number of inspections: 2
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorKimberly M. Johnson
TitleEROSION CONTROL
Phone #208-794-3958
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00122 General Inspection4/17/20134/17/20134/18/2013 7:10:36 AM PASS
permit finaled
ESC13-00013 Random Inspection4/17/20134/17/20134/17/2013 12:00:00 AMPFAIL
LM for RP: Staging retaining wall blocks and stockpile of drain rock in the ROW; stabilized construction entrance not yet installed; Silt fence not adequately trenched and is not installed along entire downslope perimeter. Due to foothill location and excavated loose soil on site (not track walked, compacted, stabilized, ect) this has a very high erosion risk and is considered enivironmentally sensitive not only because of topography but also because of drainage to Crane Creek