Inspections for the day of: Thursday, April 18, 2002.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-02848 BLD-Framing/Rough-in3/13/20024/18/20024/18/2002 12:00:00 AMAFAIL
1. (Stairway rise and run) The rise of steps and stairs shall not be less than 4 inches nor more than 7 inches. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Except as permitted for circular, winding, and spiral stairways, the run shall not be less than 11 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads or nosings. Stair treads shall be of uniform size and shape, except the largest tread run within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (1997 UBC 1003.3.3.3) Note the exception to tread and riser dimensions for private stairways and stairways to unoccupied roofs and. Also, note the exception to dimensions of risers adjoining a sloping public way. 2. need engineering for previous c/n.
BLD02-00324 BLD-Concrete4/17/20024/18/20024/18/2002 12:00:00 AMAPASS
###-#### wall ok 4/18/2002 8:42:42 AM
BLD02-00427 BLD-Framing/Rough-in4/17/20024/18/20024/18/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 04/17/2002 at 13:23:38. Contact: ###-####. Scheduled by a need to check draft stop at final.contractor via Hello! on 04/17/2002 at 13:23:38. Contact: ###-####. 4/18/2002 11:54:26 AM
BLD02-00054 BLD-Framing/Rough-in4/17/20024/18/20024/18/2002 12:00:00 AMPPASS
###-#### JERRY framing ok recived soil bearing report ok/ welders cert and special insp report ok. in archive. 4/18/2002 3:28:47 PM
BLD01-02151 BLD-Final4/18/20024/18/20024/18/2002 12:00:00 AMPPASS
harold ###-####
BLD01-02151 BLD-Final4/18/20024/18/20024/18/2002 12:00:00 AMPPASS
harold ###-####
BLD02-00187 BLD-Final4/18/20024/18/20024/18/2002 12:00:00 AMPPASS
harold ###-####
BLD02-00187 BLD-Final4/18/20024/18/20024/18/2002 12:00:00 AMPPASS
harold ###-####
BLD01-00964 BLD-Energy code compliance4/18/20024/18/20024/18/2002 12:00:00 AMPPART
###-#### PRE ROCK AREA ONLY furnce and shower/tubs ok. 4/18/2002 2:16:08 PM
BLD02-00552 BLD-Foundation4/18/20024/18/20024/18/2002 12:00:00 AMPPART
found wall- odie- ###-#### wip pending special insp. report. 4/18/2002 1:42:34 PM