ELE05-03533
| ELE-Aging Inspection | 4/18/2006 | 4/18/2006 | 4/18/2006 4:35:54 PM | | DONE |
|
|
project suc
|
ELE06-01187
| Permanent Service | 4/18/2006 | 4/18/2006 | 4/18/2006 4:02:09 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters 2 meters on permit for 1883 and 1889 address. stickered 2 meters, p/s, exst meter pak, n, ok
|
ELE06-01187
| Electrical Rough-In | 4/18/2006 | 4/18/2006 | 4/18/2006 3:39:47 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters unit 1883 and 1889 ok to cover walls and hard ceiling
|
ELE06-01328
| Temporary Service | 4/18/2006 | 4/18/2006 | 4/18/2006 3:02:26 PM | P | PASS |
|
|
lynn ###-#### met elect, told to fix 50a recpt, add abrasion prot for gec, put gec on grounded conductor term, gave elect job id stickers and told to id each t/s. t/s u/g n ok
|
ELE06-01326
| Temporary Service | 4/18/2006 | 4/18/2006 | 4/18/2006 2:59:00 PM | P | PASS |
|
|
Lynn ###-#### met elect, told to fix 50a recpt, add abrasion prot for gec,add job id sticker, t/s u/g n ok
|
ELE06-01331
| Temporary Service | 4/18/2006 | 4/18/2006 | 4/18/2006 2:57:25 PM | P | PASS |
|
|
t/s u/g n ok
|
ELE06-01314
| Electrical Rough-In | 4/18/2006 | 4/18/2006 | 4/18/2006 2:17:01 PM | P | PASS |
|
|
todd Note: pouring concrete pour back; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to pour concrete
|
ELE06-00522
| ELE-Aging Inspection | 4/18/2006 | 4/18/2006 | 4/18/2006 2:02:23 PM | | DONE |
|
|
see final
|
ELE06-00522
| Final | 4/18/2006 | 4/18/2006 | 4/18/2006 2:01:59 PM | P | PASS |
|
|
ok to final
|
ELE06-00116
| Electrical Rough-In | 4/17/2006 | 4/18/2006 | 4/18/2006 1:25:44 PM | A | PASS |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong walls and hard lids ok to cover only
|
ELE06-01312
| Temporary Service | 4/17/2006 | 4/18/2006 | 4/18/2006 11:45:06 AM | A | CANC |
|
|
Temporary power pole inspection. Please call ###-#### for questions. Thanks, Eric; Phone #: ###-#### Internet Inspection Request from: Shanna Schroeder called contr, no id or address
|
ELE06-01026
| Rough-In Permanent Service | 4/17/2006 | 4/18/2006 | 4/18/2006 10:23:26 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Latisha Peltier called cont, left corr notice, BCC all make-up shall be done, approved set of plans shall be on job, address shall be posted, 334.30 nm cable shall be secured every 4 1/2 ', 334.24 nm bend radius shall be at least 5x diameter, 314.20 boxes shall be flush with finished surface
|
ELE06-01270
| Rough-In Permanent Service | 4/17/2006 | 4/18/2006 | 4/18/2006 9:43:48 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: William Zerfas called contr, left corr notice, BCC there shall be an approved set of plans on job, all make-up shall be done, 404.8 center grip of circuit breaker handle shall not be more than 6'7" above floor,
|
ELE06-01062
| Electrical Rough-In | 4/17/2006 | 4/18/2006 | 4/18/2006 9:21:48 AM | A | PASS |
|
|
please contact Chris for ceiling cover inspection. Thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters ceiling ok to cover
|
ELE06-00790
| Electrical Rough-In | 4/17/2006 | 4/18/2006 | 4/18/2006 8:46:15 AM | A | FAIL |
|
|
Ceiling insp. - as early as possible - scheduled by Heather Packer w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer called left message, left corr notice, 300.11(A) cables shall not be supported by ceiling grid unless tested as part of fire rated assembly, 725.8 class 1,2,3 cables shall be supported by straps,staples, hangars or similar fittings designed to not damage cable, 800.24 communications cables shall be installed by fittings so as to not damage cable
|