Inspections for the day of: Tuesday, April 18, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03533 ELE-Aging Inspection4/18/20064/18/20064/18/2006 4:35:54 PM DONE
project suc
ELE06-01187 Permanent Service4/18/20064/18/20064/18/2006 4:02:09 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Celinda Winters 2 meters on permit for 1883 and 1889 address. stickered 2 meters, p/s, exst meter pak, n, ok
ELE06-01187 Electrical Rough-In4/18/20064/18/20064/18/2006 3:39:47 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Celinda Winters unit 1883 and 1889 ok to cover walls and hard ceiling
ELE06-01328 Temporary Service4/18/20064/18/20064/18/2006 3:02:26 PMPPASS
lynn ###-#### met elect, told to fix 50a recpt, add abrasion prot for gec, put gec on grounded conductor term, gave elect job id stickers and told to id each t/s. t/s u/g n ok
ELE06-01326 Temporary Service4/18/20064/18/20064/18/2006 2:59:00 PMPPASS
Lynn ###-#### met elect, told to fix 50a recpt, add abrasion prot for gec,add job id sticker, t/s u/g n ok
ELE06-01331 Temporary Service4/18/20064/18/20064/18/2006 2:57:25 PMPPASS
t/s u/g n ok
ELE06-01314 Electrical Rough-In4/18/20064/18/20064/18/2006 2:17:01 PMPPASS
todd Note: pouring concrete pour back; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to pour concrete
ELE06-00522 ELE-Aging Inspection4/18/20064/18/20064/18/2006 2:02:23 PM DONE
see final
ELE06-00522 Final4/18/20064/18/20064/18/2006 2:01:59 PMPPASS
ok to final
ELE06-00116 Electrical Rough-In4/17/20064/18/20064/18/2006 1:25:44 PMAPASS
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong walls and hard lids ok to cover only
ELE06-01312 Temporary Service4/17/20064/18/20064/18/2006 11:45:06 AMACANC
Temporary power pole inspection. Please call ###-#### for questions. Thanks, Eric; Phone #: ###-#### Internet Inspection Request from: Shanna Schroeder called contr, no id or address
ELE06-01026 Rough-In Permanent Service4/17/20064/18/20064/18/2006 10:23:26 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Latisha Peltier called cont, left corr notice, BCC all make-up shall be done, approved set of plans shall be on job, address shall be posted, 334.30 nm cable shall be secured every 4 1/2 ', 334.24 nm bend radius shall be at least 5x diameter, 314.20 boxes shall be flush with finished surface
ELE06-01270 Rough-In Permanent Service4/17/20064/18/20064/18/2006 9:43:48 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: William Zerfas called contr, left corr notice, BCC there shall be an approved set of plans on job, all make-up shall be done, 404.8 center grip of circuit breaker handle shall not be more than 6'7" above floor,
ELE06-01062 Electrical Rough-In4/17/20064/18/20064/18/2006 9:21:48 AMAPASS
please contact Chris for ceiling cover inspection. Thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters ceiling ok to cover
ELE06-00790 Electrical Rough-In4/17/20064/18/20064/18/2006 8:46:15 AMAFAIL
Ceiling insp. - as early as possible - scheduled by Heather Packer w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer called left message, left corr notice, 300.11(A) cables shall not be supported by ceiling grid unless tested as part of fire rated assembly, 725.8 class 1,2,3 cables shall be supported by straps,staples, hangars or similar fittings designed to not damage cable, 800.24 communications cables shall be installed by fittings so as to not damage cable