ELE05-00380
| Permanent Service | 4/18/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/18/2005 at 4:51:58 PM. Contact: ###-####. p/s u/g rec. ok 4/19/2005 8:51:05 AM
|
ELE05-00867
| Electrical Rough-In | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 4/19/2005 at 6:14:31 AM. Contact: ###-####. cor posted called still needs to support MC every 6ft, MC shall enter boxes with connectors attached to the box 4/19/2005 8:31:01 AM
|
ELE05-01212
| Final | 4/18/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | PASS |
|
|
Thank you, Jack! Corrections have been made. Any problems, please let me know.; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney ok 4/19/2005 8:31:16 AM
|
ELE05-01279
| Electrical Rough-In | 4/18/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | PART |
|
|
don --underground insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie u/g only bonding not ready yet 4/19/2005 9:38:02 AM
|
ELE05-01282
| Permanent Service | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g new ok
|
ELE05-01283
| Permanent Service | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g new ok
|
ELE05-00283
| Final | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | PASS |
|
|
final ok survey posted no card
|
ELE04-04122
| Permanent Service | 4/18/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | NR |
|
|
Steve Sellers Contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson contractor canceled not ready 4/19/2005 12:44:56 PM
|
ELE05-01273
| Final | 4/15/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | CANC |
|
|
###-#### - dan Note: 312 1/2 Ruby (behind house)//cancelled per dan 3:42 pm 4/18/05 BAS
|
ELE05-00946
| Final | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 4/19/2005 at 7:14:16 AM. Contact: ###-####. cor. posted called 408.4 label panel, 250.130or406.4 install non grd recept, gfci, or grd old recept in craft rm 4/19/2005 4:08:39 PM
|
ELE05-00283
| Final | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | PASS |
|
|
doug; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok survey posted 210.5(A B C) shall provide ID of grounded, and ungrounded conductors at 480 V p/s, and spray booth, oven control panels 4/19/2005 3:06:40 PM
|
ELE05-01283
| Electrical Rough-In | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | FAIL |
|
|
dean; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. not made fee due called 4/19/2005 11:58:32 AM
|
ELE05-01282
| Electrical Rough-In | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | FAIL |
|
|
dean; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. not made fee due called
4/19/2005 11:58:08 AM
|
ELE05-00223
| Final | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | NR |
|
|
###-#### - mike Note: please call 1 hr prior to inspection because the place is locked up called, contractor is not even ready he called job in for inspection before it was completed
he will reschedule when ready 4/19/2005 1:12:18 PM
|
ELE05-01315
| Permanent Service | 4/19/2005 | 4/19/2005 | 4/19/2005 12:00:00 AM | P | FAIL |
|
|
Serive & ufer ground inspection.; Phone #: ###-#### Internet Inspection Request from: Dana Moyer cor. posted 250.52(A)(3) shall install concrete encased electrode at bottom of footing called 4/19/2005 3:08:29 PM
|