ELE05-02730
| ELE-Aging Inspection | 4/19/2006 | 4/19/2006 | 4/20/2006 12:04:37 PM | | PART |
|
|
called wsuc
|
ELE06-00856
| Electrical Rough-In | 4/19/2006 | 4/19/2006 | 4/19/2006 3:45:54 PM | P | PART |
|
|
r/i and conference gate location on orchard met with dave
|
ELE05-04395
| Final | 4/19/2006 | 4/19/2006 | 4/19/2006 2:38:44 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: TJ Sturges corr. called 314.16 box fill all boxes island counter, 210.8 needs gfci MB sinks,410.8 install fixture with required clearence or remove all wiring understairs closet, 334.15 protect all exposed wiring, and install conn on all flex both ends island counter, 210.52(A) outlet spacing nupstairs bed rm by window seat/shelves, 406.4 recepts loose in boxes and not flush with plates, panel not labeled correctly schedule does not match branch circuits
|
ELE06-00309
| Final | 4/19/2006 | 4/19/2006 | 4/19/2006 1:13:55 PM | P | PASS |
|
|
please do a final elect. insp. of the barn. thank you.; Phone #: ###-#### Internet Inspection Request from: William Zerfas ok
|
ELE06-00314
| Permanent Service | 4/18/2006 | 4/19/2006 | 4/19/2006 12:26:21 PM | A | PASS |
|
|
Permanant Service / House Meter inspection, please call Tom, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters p/s u/g new for house meter ok
|
ELE06-01337
| Electrical Rough-In | 4/18/2006 | 4/19/2006 | 4/19/2006 11:36:38 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Clyde Logan corr. called 300.4 nail plates and 11/4"
|
ELE06-01338
| Rough-In Permanent Service | 4/19/2006 | 4/19/2006 | 4/19/2006 10:26:42 AM | A | PASS |
|
|
charlie Internet Inspection Request from: Melyne Davis r/i ok p/s u/g new ok
|
ELE06-01335
| Temporary Service | 4/18/2006 | 4/19/2006 | 4/19/2006 9:47:38 AM | A | PASS |
|
|
Daryl -- huge transformer/power pole across street 13960 W Wainwright; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong t/s u/g new ok
|
ELE06-01141
| Permanent Service | 4/18/2006 | 4/19/2006 | 4/19/2006 8:51:44 AM | A | FAIL |
|
|
Internet Inspection Request from: Tyler Bowen corrections not made and new violations created, 110.26(F)(2) remove bush for p/s clearence, 110.12(A) seal all unused KOs, 240.24(A) breaker spaces over 6ft7" 408.4 label panel, 314.16 box fill new jbox in basement under stairs, 250.104(A)(1) bond hot and cold called fee due posted also
|