ELE06-01312
| Temporary Service | 4/18/2006 | 4/19/2006 | 4/19/2006 3:42:26 PM | P | PASS |
|
|
Temporary power pole inspection. Please call ###-#### with questions. Thanks, Eric; Phone #: ###-#### Internet Inspection Request from: Shanna Schroeder t/s u/g n ok
|
ELE06-01342
| Electrical Rough-In | 4/19/2006 | 4/19/2006 | 4/19/2006 2:51:34 PM | P | FAIL |
|
|
###-#### - lloyd called contr, left message, left corr notice,110.12(C) there shall be no broken parts (box), 300.4(A) & (D) edge of holes and nm cable shall be 1 1/4" from edge of framing member, 314.17(C) nm cable shall be secured within 8" of box, 210.52(E) there shall be a receptacle in front of house, BCC all make-up shall be done
|
ELE06-00790
| Electrical Rough-In | 4/19/2006 | 4/19/2006 | 4/19/2006 2:24:11 PM | P | PASS |
|
|
re-insp. for ceiling - there is access now - sorry -call Chris for questions ###-#### or Mike ###-#### scheduled by Heather w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer ok to cover ceiling, corr made
|
ELE06-01063
| Final | 4/19/2006 | 4/19/2006 | 4/19/2006 1:49:02 PM | P | PASS |
|
|
chris Note: final & ceiling inspection; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover ceiling, left sticker, ok to final, signed occ card
|
ELE06-00790
| Electrical Rough-In | 4/18/2006 | 4/19/2006 | 4/19/2006 11:42:04 AM | A | NH |
|
|
Ceiling inspection - scheduled by Heather Packer w/ Doherty ; Phone #: ###-#### Internet Inspection Request from: Heather Packer called left card said to call when someone there
|
ELE05-04025
| ELE-Aging Inspection | 4/19/2006 | 4/19/2006 | 4/19/2006 9:15:03 AM | | DONE |
|
|
called contr to call for final if done
|
ELE06-01336
| Electrical Rough-In | 4/18/2006 | 4/19/2006 | 4/19/2006 8:47:22 AM | A | PASS |
|
|
john -- ###-#### call 1st for access ric for walls and hard lid ok
|