Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD05-02293 BLD-Other4/19/20064/19/20064/19/2006 4:20:58 PMPDEFR
brian Note: roof drain; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD05-03327 BLD-Other4/19/20064/19/20064/19/2006 3:39:28 PMPCANC
Scheduled by a contractor via Hello! on 4/19/2006 at 9:06:25 AM. Contact: ###-####.
BLD05-03035 BLD-Framing/Rough-in4/19/20064/19/20064/19/2006 2:00:09 PMPPASS
ron Note: call garage code; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD05-03396 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 11:22:24 AMAPASS
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD05-03398 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 11:22:11 AMAPASS
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD05-03399 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 11:20:53 AMAPASS
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD05-03060 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 11:20:36 AMAPART
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Complete shear nailing on exterior walls. Install additional 2x6 header above west door at west exterior wall. Provide approved strapping on top plates at line set pen. Provide engineering justifying additional weight on bootom chords of truuses at mech mezz.
BLD05-02381 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 10:21:42 AMAPASS
charlie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Interior steel stud walls.
BLD05-02119 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 9:42:28 AMAFAIL
Ed; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Remove tub and place 5/8 type x behind tub. 5/8 type x required at laydown parapet, westside. Also complete type x to bottom of roof deck. REmoove beam from garage wall supporting canopy from neigboring townhouse west side. Add additional studs under 2ply trusses. Remove sheet metal at mech chase and install approved fireblock material as per IRC. Fix all holes in sheetrock at 1hr walls.
BLD05-02118 BLD-Framing/Rough-in4/18/20064/19/20064/19/2006 9:29:09 AMANR
Ed; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. work still needs to be completed at mech. chase.
BLD05-02904 Extend Permit 180 days1/24/20064/19/20064/19/2006 8:04:12 AMAPASS
BLD05-02904 DOC - Permit Finaled4/19/20064/19/20064/19/2006 8:04:01 AMPPASS