Inspections for the day of: Friday, April 19, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00487 ELE-Aging Inspection4/19/20134/19/20134/22/2013 2:20:06 PM DONE
still under construction
ELE13-00631 Final4/19/20134/19/20134/19/2013 3:46:30 PMPPASS
access through side door Phone #: ###-#### >> Inspection requested via web by David Seilheimer ok final
ELE13-00419 Electrical Rough-In4/19/20134/19/20134/19/2013 3:11:12 PMPPASS
ceiling cover underground Phone #: ###-#### >> Inspection requested via web by Karl Paige ok cover ceiling, ok cover u/g
ELE13-00301 Final4/18/20134/19/20134/19/2013 1:54:25 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Camille Gulley ok final, signed card, will pull another permit for out back
ELE13-00312 Electrical Rough-In4/18/20134/19/20134/19/2013 12:58:37 PMPFAIL
Corey Phone #: ###-#### met contractor, need handicap rooms floor 6 thru 3, shall strap raceways, do make-up, 1 1/4", BCC no violations shall be retained, i.e. strap existing raceways
ELE13-00921 Final4/18/20134/19/20134/19/2013 11:58:36 AMPPASS
DUPLEX SERVICE FINAL Phone #: ###-#### >> Inspection requested via web by MARK PINNEY ok final
ELE13-00921 Permanent Service4/19/20134/19/20134/19/2013 11:57:09 AMPPASS
DUPLEX SERVICE FINAL Phone #: ###-#### >> Inspection requested via web by MARK PINNEY p/s o/h rec ok, 2 meters required
ELE13-00949 Temporary Service4/18/20134/19/20134/19/2013 10:33:13 AMAPASS
Temp Pole
Office Contact-###-#### Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE13-00225 Electrical Rough-In4/18/20134/19/20134/19/2013 9:52:26 AMAFAIL
Grid inspection Phone #: ###-#### >> Inspection requested via web by Zane Robertson called, there shall be no low voltage wiring on grid or tiles per NEC 300.11, left correction notice
ELE13-00902 Electrical Rough-In4/18/20134/19/20134/19/2013 9:01:39 AMACANC
Contact Person - Brian Phone #: ###-#### >> Inspection requested via web by Celinda Winters see rip
ELE13-00902 Rough-In Permanent Service4/19/20134/19/20134/19/2013 9:01:17 AMAPASS
Contact Person - Brian Phone #: ###-#### >> Inspection requested via web by Celinda Winters ri ok, p/s u/g rec ok
ELE13-00808 Final4/18/20134/19/20134/19/2013 8:37:01 AMAFAIL
Please call ###-#### for access info. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan open wiring, nm cable, contractor will get involved and recall
ELE13-00419 Electrical Rough-In4/19/20134/19/20134/19/2013 8:17:23 AMAFAIL
ceiling cover, under ground cover for pole lights Phone #: ###-#### >> Inspection requested via web by Karl Paige still digging for u/g, shall strap mc per NEC 330.30