Inspections for the day of: Friday, April 19, 2013.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00475 ELE-Aging Inspection4/19/20134/19/20134/22/2013 1:55:18 PM DONE
see final
ELE12-03130 Electrical Rough-In4/19/20134/19/20134/19/2013 4:16:43 PMPNR
Late afternoon, please call for access 30min ahead - don Phone #: ###-####
ELE13-00448 Final4/19/20134/19/20134/19/2013 3:28:28 PMPPASS
UL listed signs final ok
ELE12-02817 Final4/18/20134/19/20134/19/2013 3:23:21 PMPPASS
Contact is Ben MacDonagh - Phone #: ###-#### >> Inspection requested via web by Scott Campbell final ok
ELE13-00957 Rough-In Permanent Service4/19/20134/19/20134/19/2013 2:34:22 PMPPASS
Ready now Phone #: ###-#### >> Inspection requested via web by mike brown rough-in p/s u/g n ok
ELE12-01074 Final4/16/20134/19/20134/19/2013 1:44:51 PMPFAIL
Please call Mike(home owner) 30 minutes before arrival so he can be home. ###-#### Thanks. Phone #: ###-#### >> Inspection requested via web by Louis Keller NEC 680.43 (D)(4) All metal surfaces within 5 ft. of the inside walls of the hot tub shall be bonded with #8 cu to hot tub equipment. Rain gutter down spout
ELE13-00498 Electrical Rough-In4/18/20134/19/20134/19/2013 1:19:42 PMPPASS
Contact: Andy Eckhart - Temp occupancy/final inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Temporary occupancy for phase1A only ok
ELE13-00850 Electrical Rough-In4/19/20134/19/20134/19/2013 12:42:01 PMPPASS
ug conduit Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack rough-in ok cover underground
ELE13-00894 Final4/15/20134/19/20134/19/2013 12:15:13 PMPNR
brian Phone #: ###-#### not ready
ELE13-00894 Permanent Service4/19/20134/19/20134/19/2013 12:14:17 PMPPASS
p/s o/h rec ok
ELE13-00943 Electrical Rough-In4/17/20134/19/20134/19/2013 10:32:52 AMPPASS
Wall rough-in inspection. Contact Brandon Keating for questions. Phone #: ###-#### >> Inspection requested via web by Tina Payne Rough-in ok cover front entry foyer,kitchen walls only
ELE13-00391 Final4/19/20134/19/20134/19/2013 10:04:28 AMPCANC
Contact: Casey Fouts Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden
ELE13-00632 Final4/18/20134/19/20134/19/2013 10:02:44 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Nick Larson final ok
ELE13-00925 Rough-In Permanent Service4/19/20134/19/20134/19/2013 9:51:15 AMAPASS
please call with any questions. Thanks, Bob Phone #: ###-#### >> Inspection requested via web by Julie Schroder rough-in p/s u/g n ok
ELE13-00952 Electrical Rough-In4/18/20134/19/20134/19/2013 9:34:14 AMAPASS
Requesting wall rough-in inspection. electrician Cody Smith Cell ####-#### Phone #: ###-#### >> Inspection requested via web by Kevin Perez rough-in ok cover
ELE13-00562 Final4/18/20134/19/20134/19/2013 9:13:10 AMAPART
Phone #: ###-#### >> Inspection requested via web by JENNY EMEL partial final ok
ELE13-00947 Electrical Rough-In4/18/20134/19/20134/19/2013 8:26:51 AMAPASS
walls Phone #: ###-#### >> Inspection requested via web by Kevin Burke rough-in ok cover walls and underground
ELE13-00839 Final4/18/20134/19/20134/19/2013 8:12:28 AMAPASS
Mike Phone #: ###-#### correction done final ok
ELE13-00939 Temporary Service4/17/20134/19/20134/18/2013 12:23:23 PMACANC
Temp power Phone #: ###-#### >> Inspection requested via web by Zane Robertson Inspection cancelled from web by: Zane Robertson